Protective measures and behavioral rules
CAUTION !
Water from the drinking water network is used to supply the
automatic sauna splash system.
A safety combination unit for non-poisonous liquids with free
drainage according to DIN EN 1717 (Germany and EU) is installed
in the device to protect the water supply network. The splash line
from the device to the heater shower must therefore be installed in
a way that allows the line to drain by itself (declining, without water
trap, no non-return fitting).
A system separation unit according to DIN EN 1717 for non-
poisonous liquids without free drainage must be installed in the
supply line of the automatic sauna splash system when the splash
line is not self-draining (e.g. installed with incline, non-return fitting
or water trap in the pipe).
Please adhere to the locally applicable regulations!
ATTENTION !
Modification of the device is not permitted!