Table 10. Alarm Event Codes and Hex/Binary Values
Event Number
Text Message
Alarm Code
(hex)
32-bit Binary Equivalent
00
Network address
8000 0000
1
000 0000 0000 0000 0000 0000 0000 0000
01
Hardware mismatch
4000 0000
0
1
00 0000 0000 0000 0000 0000 0000 0000
02
Model number not programmed
2000 0000
00
1
0 0000 0000 0000 0000 0000 0000 0000
03
Authorization fault
1000 0000
000
1
0000 0000 0000 0000 0000 0000 0000
04
Synthesizer out-of-lock
0800 0000
0000
1
000 0000 0000 0000 0000 0000 0000
05
Reserved
06
Peripheral fault or RAM fault
0200 0000
0000 00
1
0 0000 0000 0000 0000 0000 0000
07
Voltage regulator fault detected
0100 0000
0000 000
1
0000 0000 0000 0000 0000 0000
08
Radio not calibrated
0080 0000
0000 0000
1
000 0000 0000 0000 0000 0000
09
DSP download fault
0040 0000
0000 0000 0
1
00 0000 0000 0000 0000 0000
10
NVRAM fault
0020 0000
0000 0000 00
1
0 0000 0000 0000 0000 0000
11
Reserved
12
Receiver time-out
0008 0000
0000 0000 0000
1
000 0000 0000 0000 0000
13
Time out command
0004 0000
0000 0000 0000 0
1
00 0000 0000 0000 0000
14
Reserved
15
Output power fault
0001 0000
0000 0000 0000 000
1
0000 0000 0000 0000
16
Unit address not programmed
0000 8000
0000 0000 0000 0000
1
000 0000 0000 0000
17
Data parity error
0000 4000
0000 0000 0000 0000 0
1
00 0000 0000 0000
18
Data framing error
0000 2000
0000 0000 0000 0000 00
1
0 0000 0000 0000
19
Reserved
20
Configuration error
0000 0800
0000 0000 0000 0000 0000
1
000 0000 0000
21
Running on battery
0000 0400
0000 0000 0000 0000 0000 0
1
00 0000 0000
22
Standby missing
0000 0200
0000 0000 0000 0000 0000 00
1
0 0000 0000
23
Standby has alarms
0000 0100
0000 0000 0000 0000 0000 000
1
0000 0000
24
Power output faults
0000 0080
0000 0000 0000 0000 0000 0000
1
000 0000
25
6-Volt regulator output not in valid
range
0000 0040
0000 0000 0000 0000 0000 0000 0
1
00 0000
26
DC input power is not in valid
range
0000 0020
0000 0000 0000 0000 0000 0000 00
1
0 0000
27
LNA current fault
0000 0010
0000 0000 0000 0000 0000 0000 000
1
0000