INIT [x720]
INIT [x710]
HREV
Hardware Revision
This command displays the transceiver
’
s hardware revision level. If
nothing is displayed, the hardware revision level was not programmed
by the factory.
INIT
Initialize EEPROM
Defaults
The
INIT
command is used to re-initialize the radio
’
s operating parame-
ters to the factory defaults. This is helpful when trying to resolve con-
figuration problems that might have resulted from the entry of one or
more improper command settings. If you are unsure of which command
setting caused the problem, this command allows you to return to a
known working state. The following changes to the radio are made when
INIT
is entered:
•
CTS
is set to 0
•
DATAKEY
is set to
ON
•
DEVICE
is set to
DCE
•
PTT
is set to 0
•
SCD
is set to 0
•
TOT
is set to 30 seconds and set to
ON
•
PWR
is set to +37 dBm (5 watts)
All other commands stay in the previously established setting.
Packaged Model
Initialization
This command sets the transceiver for
“
normal
”
operation
outside
the
P-20 chassis by setting the following parameters to the values shown
below:
ASENSE
ACTIVE HI
AMASK
FFFF FFFF
(assert alarm output on all alarms)
RXTOT
NONE
(receive time-out timer disabled)
Use this command to restore these three parameters to the standard
transceiver defaults if it was used in a P20 package.
This command sets the transceiver for service
within
a P-20 by setting
the following parameters to the values shown below:
ASENSE
ACTIVE LO
AMASK
FFFF 0000
(trigger on major alarms)
RXTOT
20
(20 minute time-out timer)
05-3305A01, Rev. E 27