background image

3

www.waynepumps.com

POOL 
COVER

APPLICATION AND OPERATION (CON'T)  

1.   This pump has been designed with 1-1/4 in. NPT 

discharge connection size. Attach pipe or fitting to the 
discharge or use the supplied garden hose adapter/
check valve. Thread the female end of the garden hose to 
the male end of the garden hose adapter/check valve. 

2.   Use a hose washer (not included) on the garden hose for 

correct pump operation.

3.   For best pump performance, unwind the hose before 

starting the pump. This will help remove any kinks or 
binds in the hose and allow the unit to pump with less 
restriction.

  a. DO NOT place the pump on a weak, damaged, or leaking 

pool cover. Placing the pump on a damaged pool cover 
could cause the cover to give way, or could allow the 
pump to remove treated swimming water from the pool 
in addition to rainwater.

  b. Install the “snap-on” debris strainer.  Begin by lining up 

the pump base profile with the profile of the strainer base 
using the switch housing as a guide. Tilt the pump back 
and guide the rear of the pump (opposite the discharge) 
into the strainer base. Once the rear of the pump is 
in place, gently rotate the pump down until the latch 
engages.

  c. To remove debris strainer release latch and guide pump 

out of strainer in the reverse motion of installation.

4.   With pump unplugged set the pump on the pool cover, 

where water will collect. Do NOT set the pump directly 
on mud, sand surfaces or in leaves. For best results 
make sure the pump strainer is making full contact with 
a clean area of the pool cover. This will allow the strainer 
to properly filter debris and help prevent clogging 

PULL ACROSS PUMP INSTALLATION

    To aid in pump placement on pool cover, secure provided 

25 ft. rope

 

to the pull to shore loop (Figure B).

Figure A - In-ground pool installation (cut-away view)

A2

A3

13' MAXIMUM 
PUMPING HEIGHT

AVOID PINCHING OR 

DAMAGING POWER CORD 

AND HOSE ON POOL EDGE

A1

    A1. Connect discharge hose to pump check valve and place hose 

end away from pool, where water will be displaced.

    A2. Attach provided 25 ft. rope to handle of pump, and lower pump 

onto pool cover where water will collect.

    A3. Do NOT exceed the 13 ft. maximum pumping height for this 

pump or switch may not function properly. Plug in pump to allow for 

automatic operation.

     For REMOVAL unplug pump and retrieve using 

rope.

Figure B - Pull to shore loop 

FEED ROPE 

THROUGH LOOP AND 

SECURE WITH KNOT 

    D1. Holding the provided 25 ft. rope, walk around pool until you are 

even with the pump on the opposite side.  

D2. Pull the 25 ft. rope towards you until the pump is in the center 

of the pool cover where water will collect. Secure rope for easy 

removal (see Figure E) when weather permits. Plug in pump to allow 

for automatic operation.

Figure C - Pull Across installation (side view)

C1

25 FT. ROPE 

AVOID PINCHING 

OR DAMAGING 

POWER CORD 

AND HOSE ON 

POOL EDGE

    C1. Connect provided 25 ft. rope to pull to shore loop (see Figure B) 

and discharge hose to the pump.

    C2. Place pump on pool cover near edge of pool (see Figure C). If 

floatation device is used under the pool cover, place pump at the 

lowest point on the pool cover where water will collect.

Figure D - Pull Across Installation (top view) 

D2

D1

25 FT. (INCLUDED)  

ROPE 

DROP-IN PUMP APPLICATION

 

 

 Always use debris strainer when placing pump        

  

on a pool cover. The strainer helps protect the pool cover 

from damage, filters debris, and increases pump stability.

WAPC250

Содержание WAPC250

Страница 1: ...VE STEP 3 ATTACH STRAINER STEP 4 CONNECT GARDEN HOSE STEP 5 SECURE ROPE TO STRAINER STEP 6 POSITION ON POOL COVER STEP 7 PLUG INTO GFCI OUTLET FOR FURTHER PLACEMENT TECHNIQUES AND DETAILED INSTALLATIO...

Страница 2: ...d the female end of the garden hose to the male end of the garden hose adapter check valve DESCRIPTION This portable Auto On Off Pool Cover pump is designed for automatic removal of water from a pool...

Страница 3: ...help prevent clogging PULL ACROSS PUMP INSTALLATION To aid in pump placement on pool cover secure provided 25 ft rope to the pull to shore loop Figure B Figure A In ground pool installation cut away...

Страница 4: ...the pump to operate on its side or inverted The shaft seal depends on water for lubrication allowing the pump to remain in any other orientation than upright could cause shaft seal failure or pump fai...

Страница 5: ...bly caused by debris buildup or from a frozen impeller situation caused by ice formation When the pump is activated and a locked impeller condition is detected the unit will automatically shutdown to...

Страница 6: ...specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort in clud ing negligence or otherwise s...

Страница 7: ...Notes 7 WAPC250 www waynepumps com...

Страница 8: ...OSITIONNEMENT SUR LA COUVERTURE DE LA PISCINE TAPE 7 BRANCHEMENT DANS UNE PRISE DISJONCTEUR DE FUITE LA TERRE LE WAPC250G POSS DE UNE PRISE PROT G E PAR UN DISJONCTEUR DE FUITE DE TERRE POUR LES AUTRE...

Страница 9: ...a rallonge de la pompe tomber dans la piscine ou entrer en contact avec l eau La connexion de la pompe rallonge doit tre gard e au sec et l abri de l humidit NE PAS manipuler le connecteur pr s de l e...

Страница 10: ...de traction vers le bord Figure B Figure A Installation pour une piscine enterr e vue en coupe A2 A3 TUYAU DE D CHARGE VITER TOUT PINCEMENT OU ENDOMMAGEMENT DU CORDON D ALIMENTATION ET DU TUYAU SUR L...

Страница 11: ...d eau fonctionne NE PAS laisser la pompe fonctionner sur le c t ou l envers Le joint de l arbre compte sur l eau pour sa lubrification Ainsi si la pompe n est pas maintenue droite cela pourrait La pom...

Страница 12: ...mps afin d essayer de lib rer l impulseur apr s quoi l appareil s arr tera et restera hors tension pendant 12 heures v rifiant deux fois par jour si l impulseur est lib r Une fois que la pompe sera no...

Страница 13: ...ts l gaux qui varient d une juridiction l autre En aucun cas soit par suite d une rupture de contrat de garantie acte dommageable y compris la n gligence ou autre ni WAYNE Pumps ni ses fournisseurs ne...

Страница 14: ...Remarques 14 FR www waynepumps com Manuel de pi ces et mode d emploi...

Страница 15: ...DE JARD N PASO 5 SUJETE LA CUERDA AL FILTRO PASO 6 COLOQUE LA BOMBA SOBRE LA CUBIERTA DE PISCINA PASO 7 ENCHUFE EN UN TOMACORRIENTE GFCI WAPC250G TIENE ENCHUFE PROTEGIDO CON GFCI PARA OBTENER M S T C...

Страница 16: ...NAR lesiones graves o la muerte Esta unidad NO est dise ada para usarse como una bomba de sumidero o en aplicaciones de sumidero Esta unidad NO est dise ada para usarse en tanques s pticos ni en s tan...

Страница 17: ...25 pies que se suministra al pestillo de sujeci n Figura B Figura A Instalaci n en piscina enterrada vista seccionada A2 A3 MANGUERA DE DESCARGA EVITE APRETAR O DA AR EL CABLE DE CORRIENTE Y LA MANGUE...

Страница 18: ...que la detecci n de agua funcione EVITE que la bomba funcione de costado o en posici n invertida El sello del eje utiliza agua para su lubricaci n Si la bomba permanece en cualquier otra orientaci n q...

Страница 19: ...tivada y se detecta una condici n de bloqueo del impulsor la unidad se apaga autom ticamente para evitar que el motor se sobrecaliente La bomba continuar este ciclo de encendido apagado durante un tie...

Страница 20: ...os derechos legales que pueden variar de un estado a otro Bajo ning n concepto ya sea por incumplimiento del contrato de garant a agravio incluida la negligencia o de otro modo WAYNE Pumps o sus prove...

Отзывы: