7. Install discharge plumbing according to local, regional
and state codes. Rigid PVC pipe is recommended.
8.
If required, drill 1/8 in. “weep” hole in the discharge pipe 1
in. above the pump discharge. Water stream will be
visible from the hole when the pump is running. The hole
must be cleaned periodically.
9. Install a union to allow for easy removal of the pump for
cleaning or service.
10. Install a check valve (required) to prevent back-flow. The
check valve may be positioned just above the basin to
allow easy removal of the pump for cleaning and service.
11. Install a gate valve or ball valve if required by local,
regional or state code.
12. Secure power supply cord to discharge pipe using cable
or zip ties to prevent possible switch entanglement.
13. Connect pump power supply cord to a ground fault circuit
interrupter (GFCI) receptacle.
14. Fill the basin with water. The pump will start when the
water level has reached the switch-on level.
15. The pump will stop when the water level has reached the
switch-off level.
16. Verify the switch is operating without any obstruction
from the pump, piping and basin.
17. Fill the basin with water again. While the pump is
draining the basin, verify the discharge pipe is carrying
the water to a point at least 3 ft. away from the
foundation. If the discharge line is exposed to freezing
temperatures, the pipe must be positioned in a downward
slope away from the foundation so any remaining water
will drain away and not freeze.
18. Secure the basin cover and gasket to the basin to
prevent debris from falling into the basin, prevent
personal injury, and to contain gases and/or odors.
This pump is not designed to handle salt water, brine,
laundry discharge, water softener, sewage, grey water, or
any other application which may contain caustic chemicals
and/or foreign materials. Pump damage could occur if used
in these applications and will void warranty