72
Larsen @ Cafeteria
. Location information is added to the alert text if the Include Location feature is
enabled in General Settings.
Resident
EP
The resident that the sensor is assigned to. Typically used with mobile sensors. Resident can be an
optional assignment that can improve the detail in an alert message, as required. If a resident is
assigned to a sensor, and a room is assigned to a resident in the Residents table, that room will take
precedence over the Room assigned in this table when the alert is processed.
Action
EP
A value that can be used to generate a single click web based action when the action icon is clicked for a
selected alert in the Alert Client app.
Action Type
EP
Tells the server how to format the action value so that the Alert Client can perform the appropriate
action when the action icon is tapped for a given alert.
Schedule
EP
The Alert Processing Schedule assigned to the sensor. If no schedule is assigned, alerts associated with
the sensor may be monitored continuously. Schedules can be assigned in other areas of the system,
such as Rooms, Residents and Wireless Receivers. Where schedules are layered during the process of
generating alerts or delivering alert notifications, for the system elements where a schedule is assigned,
if any one or more of those assigned schedules indicate that the alert should be generated, the alert will
be generated.
Audio File
EP
The audio file assigned to the sensor. The audio file will be played by the either the audio file to two
way radio interface device or in a Digital Alert Viewer in either a desktop browser or on a digital TV
screen. Default is Unassigned. Audio files are configured in the Outputs/Audio Files section.
MNS Msg
The priority message to be used for mass notification, including being displayed on all LED Displays
connected to the system, if the associated alert is activated. Default is Unassigned. Once the alert is
completed, the priority message will be removed from all LED Displays. Note that any MNS Msg defined
here can be overridden by any defined within the Rules and Filters section.
Delete
If the Delete function fails, it is probably caused by the existence of associated
Zones/Inovonics
Sensors
records, which should be removed first before the deletion can be successful.