Broadband Analyzer/Generator
ANT-20/ANT-20E
TB-14
Technical Background
Test type: “ATM Layer QoS (SVC) - Called”
Settings
Basically the same as for “Calling” mode (see Sec. 2.4) but the test types in “Configure
instrument” are reversed.
Time sequence
After the measurement is started (Application Manager) the following automatic sequence
begins. The sequence is split into 5 phases:
Fig. TB-10
Time sequence at ATM traffic generation, “Called” mode: During the gate time, two calls were
accepted
Phases
1. The measurement is started:
The layer 2 signaling (SSCOP) connection is set up.
2. A connection (virtual channel) is switched as soon as a call is received.
3. The connection is set up. Test traffic is generated if it has been enabled by the user.
4. The connection is cleared down. The QoS parameters are saved in the log file as required.
The measurement is stopped. An existing connection is cleared down. The QoS parameters
are saved in the log file as required.
Phases 2, 3 and 4 can be repeated as many times as required during the measurement interval.
Signaling
traffic
SSCOP
connection
Phase
1
2
3
4
Test channel
Test traffic
Results display
Signaling
conditions
NCS
QoS
connecting
connected
discon.
discon.
connecting
connected
disconnected
disconnected
discon.
connec-
connected
disconnected
1) VI “ATM Test Results”
2) Not Connected Seconds
1
2
Gate time
t
2
3
5
disconnected
connecting
connected
connected
connecting
discon.
discon.
ting
Содержание ANT-20
Страница 8: ...Broadband Analyzer Generator ANT 20 ANT 20E vi Notes ...
Страница 64: ...Broadband Analyzer Generator ANT 20 ANT 20E O 46 Operation Notes ...
Страница 110: ...Broadband Analyzer Generator ANT 20 ANT 20E TB 16 Technical Background Notes ...
Страница 126: ...Broadband Analyzer Generator ANT 20 ANT 20E iv Notes ...