You have completed the installation of your new Reverse Osmosis system.

Please Follow the Startup Instructions.

Flushing of the tank 3 times is only necessary during the initial startup and after replacing 
the membrane.

Note:

Start up Instructions

Step  1 

Turn on the incoming hot 

and

 cold water angle stop valves.  

 

 

Turn both of the adapt-a-valves on and check the system for leaks and tighten fittings 

  as 

necessary. 

Note: 

  

Check daily over the next week 

 

  

to ensure no leaks are present.  

Step  2 

Plug the (24 volt) transformer 

 

 

power cord connector into the 

 

 

ESOV as pictured.

Step  3 

Plug the transformer into the 

 

 

electrical outlet under the sink.

Step  4 

Ensure ball valve on tank is open.

Step  5 

Open the RO faucet and leave it 

 

 

open until water begins to drip. 

 

 

Then close  the faucet. 

 

 

The tank will take between 2 - 4  

 

 

hours to fill.  

Note:   

If no water comes out of the RO 

 

 

faucet after a few minutes check 

 

 

the power outlet!  It is possible that the power outlet you used for the RO unit  

 

 

is controlled by the garbage disposal switch. To test - Unplug the garbage 

 

 

disposal and flip the garbage disposal switch to “on” . If the RO pump turns on  

 

 

and water starts to drip out of the RO faucet you will need to connect the system  

 

 

to a different power outlet socket.

Step  6 

After the tank has filled once, open the RO faucet and drain the tank.  

Note:   

Water may be cloudy or milky due to air in the system and carbon particles flushing out  

 

 

of the final polishing filter.  This condition will resolve itself after flushing a couple of 

 

 

tanks of water.    

 

 

Step  7 

Complete step #6 two more times.  The process of flushing the system first three times  

 

 

should take about one day to complete.  The fourth tank can be used for drinking water.

Warning:

  

To prevent the possibility of electrical shock, clean up any water on 

cabinet floor and dry all water from outside of RO unit.   

ESOV

Содержание ZRO-PURE

Страница 1: ...Inc 8716 W Ludlow Drive Suite 1 Peoria AZ 85381 Phone 800 752 5582 www wattspremier com Fax 623 866 5666 Save manual for future reference Warning Please read carefully before proceeding with installat...

Страница 2: ...ed change 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recom...

Страница 3: ...Tube Connection From Adapt A Valve to Pump 9 Green Tube Connection From RO System to ESOV 9 Blue Tube Connection From RO System to ESOV 9 Blue Tube Connection ESOV 9 Tank Ball Valve Installation 10 Bl...

Страница 4: ...Maximum 100 F 37 8 C Minimum 40 F 4 4 C Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 180...

Страница 5: ...TUBE ZRO PURE Storage Tank Booster Pump Transformer ADAPTA VALVE HOT COLD Plumbing Diagram and Parts List Not recommended for use on homes equipped with tankless water heaters Contact Watts Premier fo...

Страница 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Страница 7: ...rt all the way into the end of the tube See Picture Insert the blue tube into the end of the faucet shank and use a wrench to tighten the brass nut securely Step 9 This faucet provides an electronic m...

Страница 8: ...ake sure that the black collet is installed in to the 1 4 opening on the Adapt a valve Don t forget to install the white compression washer with the 3 8 configuration Brass adapter A does not need to...

Страница 9: ...e to Pump Insert the open end 1 4 green tube from the Adapt a Valve into the 1 4 open end of the booster pump quick connect union Make sure the tube is pushed in all the way to the tube stop Green Tub...

Страница 10: ...be stop see page 9 for quick connect fitting use directions Step 20 Note Set the blue ball valve knob in line with the blue tube this is the open position Teflon tape must be applied in a clockwise di...

Страница 11: ...hours to fill Note If no water comes out of the RO faucet after a few minutes check the power outlet It is possible that the power outlet you used for the RO unit is controlled by the garbage disposal...

Страница 12: ...ge However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to replace the membrane Premier recommends replacing the membr...

Страница 13: ...tem Plug in the transformer Check frequently over the next 24 hours to ensure no leaks are present Step 4 Step 3 Note Step 2 Close the RO faucet allowing the storage tank to fill with water It may tak...

Страница 14: ...upply to the RO and unplug transformer Open the RO Faucet and allow water to drain from the tank until it is completely empty Step 2 Check air pressure in the storage tank when you notice a decrease i...

Страница 15: ...Air Gauge for best results The empty tank pressure should be 5 7 psi See page 14 4 Noise Water from faucet Crimp or restriction Check tubing and straighten or repair as necessary vent hole or noise f...

Страница 16: ...0 ml 3 ml 99 99 7 44 50psi 18 minimum 50 000 mL N A Fluoride Reduction 8 7 0 19 97 0 7 24 50psi 0 3 8 0 10 1 5 Lead Reduction 0 15 0 002 98 8 7 39 50psi 0 005 0 15 10 0 0107 Nitrate 27 3 8 86 0 7 24 5...

Страница 17: ...ee chlorine or combined chlorine is used in the water system This Premier reverse osmosis system is designed to remove up to 98 of pentavalent arsenic It will not convert trivalent arsenic to pentaval...

Страница 18: ...Page 18 Nitrate Nitrite Test Instruction...

Страница 19: ...nge kit which includes all replacement filters needed Call 1 800 752 5582 or buy on line at www wattspremier com All prices subject to change without notice Connect your RO Pure system to your refrige...

Страница 20: ...Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 All In One reversible High Flow Filter Replacement filter Deluxe 5 Way Massaging Spray S...

Страница 21: ...the safety of your personal information Premier collects personal information when you register with Premier This information is stored in our data base and we do not rent sell or share personal info...

Страница 22: ...y USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of Purchase ___________________ Date of Install _______________________ Installed By...

Страница 23: ...rchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months Carbon Post Filter 12months Model Number ____...

Страница 24: ...g water pressure must be between 40 and 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do...

Отзывы: