manualshive.com logo in svg
background image

Page 12

  
 
 
 
  

 

 

 

 
 
 

 
 

 

Place a towel under the RO module to catch any excess water that 

may drip out from the filters during the changeover.

Step  1     

Your RO module is equipped with valved heads which will automatically turn off the water supply to 

each filter when the filter is released, thus you do not need to turn off the incoming water supply at the 

Adapt-a-Valve. The RO faucet must be off when filters are replaced. To make the removal of the filter 

cartridges easier, the heads & cartridges may be swiveled up to 90 degrees as shown in the pictures below.

Step  2    

To  install  a  filter  cartridge:

 Remove the seal cap and insert 

the cartridge into the valved head until you hear an audible “click” 

(the  button  does  not  need  to  be  pressed  to  install  new  filters).    

Step 3   

To remove a filter cartridge:

 Push & hold the button on the 

valved head above the filter. Pull cartridge downward (from the 

head) to remove. Release button and discard old filter.  

Changing The Filter Cartridges

Membrane Replacement (2 - 5 Years)

√ 

One Membrane    

(50 GPD Green Label P/N: 105331)

Replace: 

 

Membranes have a life expectancy between 2 and 5 years, depending on the incoming water conditions 

and the amount the RO system is used. This reverse osmosis membrane is critical for effective reduction of total 
dissolved solids (TDS). The product water should be tested periodically to verify that the system is performing 
satisfactorily.

 

Normally, a membrane would be replaced during a semiannual or annual filter change.  However, if at any 

time you  notice a reduction in water production or an unpleasant taste in the reverse osmosis water, it could be 
time to replace the membrane. Premier recommends replacing the membrane when TDS reduction falls below 
75%.
 

A water sample may be sent to Premier for a free diagnosis of your membranes performance.  To send 

a water sample, use 2 clean containers and fill 1/2 cup of tap water in one container and 1/2 cup of RO water in 

2nd container. Clearly label each sample. Send the samples to the address listed on the cover of this manual 
attention “Water Samples”. Premier will test the water and mail or call you with the results.

To reset the electronic monitor during replacement of filters, simply 

pry out the black rubber battery drawer from the faucet handle using 

a flat head screwdriver, wait a few moments and reinsert.

Note:

This reverse osmosis system contains a replaceable component (the RO membrane) which is critical to the 

efficiency  of  the  system.  Replacement  of  this  reverse  osmosis  membrane  should  be  with  one  of  identical 

specifications  as  defined  by  Premier  to  assure  the  same  efficiency  and  contaminant  reduction  performance.

Annual Maintenance

 

-(Sanitization Recommended See PG.13)

√ 

One sediment filter  

(Red Label P/N: 105311)

√ 

One carbon pre-filter  

(Yellow Label P/N: 105351)

 One carbon post-filter   (Blue Label P/N: 105341) 

Replace:

√ 

One sediment filter  

(Red Label P/N: 105311)

√ 

One carbon pre-filter  

(Yellow Label P/N: 105351)

Replace:

6 Month System Maintenance

Tip:

This is a good time to check the air pressure in your storage 
tank. For instructions please see page 14.

Flush first tank full after completing the annual maintenance.

Note:

Содержание ZRO-PURE

Страница 1: ...Inc 8716 W Ludlow Drive Suite 1 Peoria AZ 85381 Phone 800 752 5582 www wattspremier com Fax 623 866 5666 Save manual for future reference Warning Please read carefully before proceeding with installat...

Страница 2: ...ed change 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recom...

Страница 3: ...Tube Connection From Adapt A Valve to Pump 9 Green Tube Connection From RO System to ESOV 9 Blue Tube Connection From RO System to ESOV 9 Blue Tube Connection ESOV 9 Tank Ball Valve Installation 10 Bl...

Страница 4: ...Maximum 100 F 37 8 C Minimum 40 F 4 4 C Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 180...

Страница 5: ...TUBE ZRO PURE Storage Tank Booster Pump Transformer ADAPTA VALVE HOT COLD Plumbing Diagram and Parts List Not recommended for use on homes equipped with tankless water heaters Contact Watts Premier fo...

Страница 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Страница 7: ...rt all the way into the end of the tube See Picture Insert the blue tube into the end of the faucet shank and use a wrench to tighten the brass nut securely Step 9 This faucet provides an electronic m...

Страница 8: ...ake sure that the black collet is installed in to the 1 4 opening on the Adapt a valve Don t forget to install the white compression washer with the 3 8 configuration Brass adapter A does not need to...

Страница 9: ...e to Pump Insert the open end 1 4 green tube from the Adapt a Valve into the 1 4 open end of the booster pump quick connect union Make sure the tube is pushed in all the way to the tube stop Green Tub...

Страница 10: ...be stop see page 9 for quick connect fitting use directions Step 20 Note Set the blue ball valve knob in line with the blue tube this is the open position Teflon tape must be applied in a clockwise di...

Страница 11: ...hours to fill Note If no water comes out of the RO faucet after a few minutes check the power outlet It is possible that the power outlet you used for the RO unit is controlled by the garbage disposal...

Страница 12: ...ge However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to replace the membrane Premier recommends replacing the membr...

Страница 13: ...tem Plug in the transformer Check frequently over the next 24 hours to ensure no leaks are present Step 4 Step 3 Note Step 2 Close the RO faucet allowing the storage tank to fill with water It may tak...

Страница 14: ...upply to the RO and unplug transformer Open the RO Faucet and allow water to drain from the tank until it is completely empty Step 2 Check air pressure in the storage tank when you notice a decrease i...

Страница 15: ...Air Gauge for best results The empty tank pressure should be 5 7 psi See page 14 4 Noise Water from faucet Crimp or restriction Check tubing and straighten or repair as necessary vent hole or noise f...

Страница 16: ...0 ml 3 ml 99 99 7 44 50psi 18 minimum 50 000 mL N A Fluoride Reduction 8 7 0 19 97 0 7 24 50psi 0 3 8 0 10 1 5 Lead Reduction 0 15 0 002 98 8 7 39 50psi 0 005 0 15 10 0 0107 Nitrate 27 3 8 86 0 7 24 5...

Страница 17: ...ee chlorine or combined chlorine is used in the water system This Premier reverse osmosis system is designed to remove up to 98 of pentavalent arsenic It will not convert trivalent arsenic to pentaval...

Страница 18: ...Page 18 Nitrate Nitrite Test Instruction...

Страница 19: ...nge kit which includes all replacement filters needed Call 1 800 752 5582 or buy on line at www wattspremier com All prices subject to change without notice Connect your RO Pure system to your refrige...

Страница 20: ...Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 All In One reversible High Flow Filter Replacement filter Deluxe 5 Way Massaging Spray S...

Страница 21: ...the safety of your personal information Premier collects personal information when you register with Premier This information is stored in our data base and we do not rent sell or share personal info...

Страница 22: ...y USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of Purchase ___________________ Date of Install _______________________ Installed By...

Страница 23: ...rchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months Carbon Post Filter 12months Model Number ____...

Страница 24: ...g water pressure must be between 40 and 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do...

Отзывы: