ZRO-Pure
System conforms to Standard 58 for specific claims
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Change time Frame
Cost
Sediment Pre-filter:
#105311
6 Months
$ 9.95
Carbon Pre-filter:
#105351
6 Months
$15.95
Post Carbon filter
#105341
12 Months
$15.50
50 GPD R.O. Membrane:
#105331
2 to 5 years
$89.00
Concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving
the system as specified in NSF/ANSI 58. This system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or
arsenate) at concentrations of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used
on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent
arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic, Please see the
Arsenic Facts section of the Performance Data Sheet for further information
Avg. In.
Avg. Eff.
% Reduction pH
Pressure
Max Eff.
Inf. challenge
Max Allowable
(mg/L)
(mg/L) mg/L
concentration
concentration
mg/L
mg/L
Arsenic (Pentavalent)
.310
0.001
99.6%
7.24
50psi
0.002
0.30±10%
0.010 mg/L
Barium Reduction
9.2
0.08
99.0%
7.64
50psi
0.12
10.0±10%
2.0
Cadmium Reduction
0.031
0.0004
98.0%
7.49
50psi
0.0008
0.03±10%
0005
Chromium (Hexavalent)
0.30
0.002
99.0%
7.24
50psi
0.004
0.03±10%
0.1
Chromium (Trivalent)
0.30
0.001
99.0%
7.64
50psi
0.002
0.03±10%
0.1
Copper Reduction
3.2
0.02
99.0%
7.40
50psi
0.04
3.0±10%
1.3
Cysts
92,000#/ml
3 #/ml
99.99%
7.44
50psi
18 minimum 50,000/mL
N/A
Fluoride Reduction
8.7
0.19
97.0%
7.24
50psi
0.3
8.0±10%
1.5
Lead Reduction
0.15
0.002
98.8%
7.39
50psi
0.005
0.15±10%
0.0107
Nitrate
27
3.8
86.0%
7.24
50psi
4.3
27.0 ±10%
10.0
Nitrite
3.1
0.41
86.0%
7.24
50psi
0.46
3.0 ±10%
1.0
N Nitrite
30
4.2
86.0%
7.24
50psi
4.8
30.0 ±10%
10.0
Radium 226/228
25pCi/L
5pCi/L
80.0%
7.24
50psi
5pCi/L
25pCiL±10%
5pCiL
Selenium
94.85
<0.2
97.0%
7.24
50psi
<0.2
0.10±10%
0.05
TDS
741
22
97.0%
7.28
50psi
26.0
750±40mg/L
187
Turbidity
11.3
0.1
99.0%
7.43
50psi
0-1
11±1mg/L
0.5NTU
Depending on water chemistry, water temperature, and water pressure Premier’s R.O. Systems production and performance will vary.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY
INFORMATION.
Phone: (480) 675-7995 Fax: (623) 866-5666 Email: [email protected]
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that
is microbiologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
2. This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and
is certified for nitrite/nitrate reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater. If your water supply is under 40 psi Premier
recommends the use of a RO booster pump for proper operation.
3. Operating Temperature:
Maximum: 100°F (40.5°C)
Minimum: 40° (4.4°)
4. Operating Water Pressure:
Maximum: 85 psi (6.0kg/cm2)
Minimum: 40 psi (2.8kg/cm2)
5.
pH
2
to
11
6. Maximum Iron present in incoming water supply must be less than 0.2 ppm.
7. Hardness of more than 10 grains per gallon (170 ppm) may reduce RO membrane life expectancy.
8. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.