Introduction

Thank you for your purchase of the Premier Reverse Osmosis 

(RO) water treatment system.

 This Premier water treatment system 

has been designed and tested to provide you with high quality 

drinking water when installed, maintained and used in accordance 

with the instructions in this Manual, and any requirements of local, 

state and federal law. Failure to do so could result in personal injury, 

property damage or damage to the equipment. This Manual should 

be considered a permanent part of your system and should be kept 

available for easy reference by any user.
If this system or any of its parts becomes damaged or needs repair, 

turn off the water supply, stop using the system and contact an 

experienced service individual immediately.
If on-product labels or this Manual are misplaced, damaged or il-

legible, or if you require additional copies, please contact Watts for 

these items at no charge.
If you are ever uncertain about a particular task or the proper method 

of operating this system, consult this Manual, contact a licensed 

plumber, or contact Watts at 800-752-5582

Your Reverse Osmosis System:

Osmosis is the process of water passing through a semi permeable 

membrane in order to balance the concentration of contaminants 

on each side of the membrane. A semi permeable membrane is a 

barrier that will allow clean drinking water through, but will reduce 

the passage of containments such as arsenic or lead*. This reverse 

osmosis system also utilizes carbon block filtration technology, and 

can therefore provide a higher quality drinking water than carbon 

filtration systems alone.

*This product cannot effectively reduce the trivalent form of  

Arsenic. Please read the Arsenic Fact Sheet and Performance 

Data Sheet in the back of this manual for additional information.

The Stages of Filtration

Your system is a four stage RO which is based upon separate  

treatment segments within the one complete water filtration system. 

These stages are as follows: 

Stage 1 –  Sediment filter, recommended change 6 months. 

The first stage of your RO system is a 5 micron  

sediment filter that traps sediment and other particulate 

matter like dirt, silt and rust which affect the taste and  

appearance of your water. 

Stage 2 –

  

Carbon filter, recommended change 6 months.  

The second stage contains a 5 micron carbon block filter. 

This helps ensure that chlorine and other materials that 

cause bad taste and odor are greatly reduced.

Stage 3 -

  

Membrane, recommended change 2-5 years. 

Stage three is the heart of the reverse osmosis system, 

the 50GPD (Gallons Per Day) RO membrane. This semi 

permeable membrane will effectively remove TDS, Sodium 

and a wide range of contaminants such as Perchlorate, 

Chromium, Arsenic, Copper, Lead as well as Cysts, such 

as Giardia and Cryptosporidium. Because the process  

of extracting this high quality drinking water takes time, 

your RO water treatment system is equipped with a  

storage tank. 

Stage 4 -  Carbon post filter, recommend change 12 months.

 

The final stage is a high quality carbon filter. Drinking water 

enters this filter after the water storage tank and it is used 

as a final polishing filter. 

NOTICE

 Filter & Membrane life may vary based upon local water  

conditions and/or use patterns.

Maximum

Minimum

Operating Temperatures

100°F (37.8°C)

40°F (4.4°C)

Operating Pressure

85 psi (6.0 kg/cm2)

40 psi  

(2.8 kg/cm2)

pH Parameters

11

2

Iron

0.2 ppm

TDS 

(Total Dissolved Solids)

< 1800 ppm

Turbidity

< 5 NTU

Hardness

Maximum 10 Grains  

Per Gallon *

 Operational Parameters

NOTICE

Installation must comply with State and local plumbing regula-

tions. Do not use with water that is micro biologically unsafe or 

of unknown quality without adequate disinfection before or after 

the system.
System is intended to be installed using the cold water  

supply only.

Hardness:

 Recommended hardness not to exceed 10 grains per 

gallon, or 170ppm. 
*  System will operate with hardness over 10 grains but the mem-

brane life may be shortened. Addition of a water softener may 

lengthen the membrane life.

Water Pressure:

 The operating water pressure in your home should 

be tested over a 24 hour period to attain the maximum pressure. If 

the incoming water pressure is above 100 psi then a water pressure 

regulator is required. A booster pump is needed for incoming water 

pressure under 40psi. 

Copper Tubing:

 Reverse Osmosis water should not be run through 

copper tubing as  the purity of the water will leach copper causing 

an objectional taste in water and pin holes may form in the tubing. 

Watts Premier supplies speciality filters (part numbers WP107008, 

WP560060 and WP560059) that can be used if copper tubing fol-

lows the Reverse Osmosis unit. Be sure to follow any state or local 

regulations during installation.

Contents of Reverse Osmosis (RO) System

Please make sure all of the items listed below are contained 

in the box. If any of the items are missing please contact 

Watts Premier at 800-752-5582 prior to installing.

1 Tank – White
1 RO Module (complete with filters)
1  Parts Bag 
1 Faucet Box
1 Manual

IOM-Premier-RO-PURE.indd   2

7/10/20   2:32 PM

Содержание Premier RO-PURE

Страница 1: ...to a surface strong enough to support its weight System tested and certified by WQA against NSF ANSI Standard 58 for the reduction of the claims specified on the performance data sheet and to NSF ANSI...

Страница 2: ...ly reduced Stage 3 Membrane recommended change 2 5 years Stage three is the heart of the reverse osmosis system the 50GPD Gallons Per Day RO membrane This semi permeable membrane will effectively remo...

Страница 3: ...134018 1 4 QC x 1 4 FPT Tank Ball Valve 7 WP228173 Fitting 3 8 Stem x 1 4 QC Adapter 8 WP164056 Drain Saddle 3 8 Kit 9 WP610109 4 Green 1 4 Tubing 10 WP610113 4 Blue 1 4 Tubing 11 WP400048 3 Black 3 8...

Страница 4: ...itting With the collet held in this position the tube can be removed The fitting can then be reused STEP 1 NOTICE Water supply line to the system must be from the cold water supply line only Hot water...

Страница 5: ...faucet may push up out of position Prior to the install hold the faucet as shown in the picture and pull down on the wing nut This will ensure that the O rings are in their proper position and that y...

Страница 6: ...ough one side of the drain pipe Step C The drain saddle must be installed at least 1 above the nut of the P Trap elbow or cross bar from the garbage disposal to insure proper drainage Using the 3 8 dr...

Страница 7: ...en so it can easily be closed to prevent water flowing to the ice maker during start up and periodic maintenance An Ice maker Connection Kit can be purchased through Premier Startup NOTICE If your RO...

Страница 8: ...conditions and the amount the RO system is used This reverse osmosis membrane is critical for effective reduction of total dissolved solids TDS The product water should be tested periodically to verif...

Страница 9: ...es then continue rinsing eye Call a poison control center or doctor for treatment advice Check Air Pressure in the Tank Procedure for Extended Non Use More than 2 months NOTICE Check air pressure only...

Страница 10: ...water Set tank air pressure between 5 7psi See previous page Low Pressure in Tank Use a Digital Air Gauge for best results The empty tank pressure should be 5 7psi See Page 9 4 Noise Water from faucet...

Страница 11: ...S Total Dissolved Solids not to exceed 1800 ppm DESCRIPTION PART CHANGE TIME FRAME Sediment Pre Filter WP105311 6 Months Carbon Pre Filter WP105351 6 Months Final Carbon Filter WP105341 12 Months 50 G...

Страница 12: ...7 43 50 psi 0 1 11 1 mg L 0 5 NTU Nitrate Nitrite N A N A 83 30 N A N A N A N A N A Recovery 25 5 Daily Production Rate 23 5 GPD Efficiency 12 8 This system has been tested according to NSF ANSI 58 fo...

Страница 13: ...senic may not con vert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is us...

Страница 14: ...cord DATE OF PURCHASE MODEL NUMBER SERIAL NUMBER DATE OF INSTALL INSTALLED BY INSTALLED BY DATE SEDIMENT 6 MONTHS PRE CARBON 6 MONTHS POST CARBON 1 YEAR RO MEMBRANE 2 5 YEARS IOM Premier RO PURE indd...

Страница 15: ...ions from abuse misuse misapplication improper maintenance neglect alteration accidents casualties fire flood freezing environmental factors water pressure spikes or other such acts of God This warran...

Страница 16: ...IOM Premier RO PURE indd 16 7 10 20 2 32 PM...

Отзывы: