manualshive.com logo in svg
background image

8

 Maintenance

 

WARNING

!

For proper performance and to help avoid exposure to 

contaminants, this system must be installed, maintained and 

operated as specified in this Manual. 
It is important to change out your filters at the recommended 

intervals as indicated in this system manual. When replacing 

the filter elements, pay special attention to any cleaning in-

structions. Should you have any further questions please refer 

to our web site at www.premierh2o.com or call our customer 

service department at 1-800-752-5582.
With proper installation and maintenance, this system will 

provide you with high quality water for years to come. All  

of Premier’s water enhancement products are rigorously 

tested by independent laboratories for safety and reliability. 

If you have any questions or concerns, please contact our 

customer service department at 1-800-752-5582 (outside USA 

480-675-7995) or refer to our on-line troubleshooting guide at 

www.premierh2o.com.
 

NOTICE

If your RO system is connected to a refrigerator / ice maker, 

you must turn off the connection to that appliance during the 

system maintenance.
 

NOTICE

The following is a minimum replacement schedule – More  

frequent filter replacement may be required depending on 

your particular water conditions and use.   

 6 Month Maintenance

*Order filters by calling 1-800-752-5582 or buy online at  

www.premierh2o.com.

Replace:

   (1) Sediment Filter 

Red Label P/N: WP105311 

(1) Carbon Block Filter 

Yellow Label P/N: WP105351

Includes: 

  (1) RO Membrane 

(50 GPD Green Label P/N: WP105331)

Membranes have a life expectancy between 2 and 5 years, de-

pending on the incoming water conditions and the amount the 

RO system is used. This reverse osmosis membrane is critical for 

effective reduction of total dissolved solids (TDS). The product water 

should be tested periodically to verify that the system is performing 

satisfactorily.
Normally, a membrane would be replaced during a semiannual or 

annual filter change. However, if at any time you notice a reduction in 

water production or an unpleasant taste in the reverse osmosis wa-

ter, it could be time to replace the membrane. Premier recommends 

replacing the membrane when TDS reduction falls below 75%.

Membrane Replacement

 Annual Maintenance

Replace: 

  (1) Sediment Filter 

Red Label P/N: WP105311 

(1) Carbon Pre-Filter 

Yellow Label P/N: WP105351 

(1) Carbon Post-Filter 

Blue Label P/N: WP105341 

 

 

This is a good time to check the air pressure in your storage 

tank. For instructions please see page 9.
Flush first tank full after completing the annual maintenance.  
Step A – 

 Place a towel under the RO module to catch any excess 

water that drips out from the filters during the changeover.

Step B – 

 To make the removal of the 

filter housings easier, the heads 

and housings may be lifted up 

to 90° as shown in the pictures  

to the right.  

To remove a filter cartridge: 

Push & hold the button on the 

valve head above the filter. Pull 

cartridge downward (from  

the head) to remove. Release 

button and discard old filter.

NOTICE

Step C – 

 Make sure to remove the cap off of the new replacement 

filter.  

To install a filter cartridge: 

Remove the seal cap and 

insert the cartridge into the valve head until you hear an 

audible “click” (the button does not need to be pressed to 

install new filters).

To reset the electronic monitor during replacement of filters, 

simply slide out the battery from the base of the faucet  

and reinsert.

IOM-Premier-RO-PURE.indd   8

7/10/20   2:32 PM

Содержание Premier RO-PURE

Страница 1: ...to a surface strong enough to support its weight System tested and certified by WQA against NSF ANSI Standard 58 for the reduction of the claims specified on the performance data sheet and to NSF ANSI...

Страница 2: ...ly reduced Stage 3 Membrane recommended change 2 5 years Stage three is the heart of the reverse osmosis system the 50GPD Gallons Per Day RO membrane This semi permeable membrane will effectively remo...

Страница 3: ...134018 1 4 QC x 1 4 FPT Tank Ball Valve 7 WP228173 Fitting 3 8 Stem x 1 4 QC Adapter 8 WP164056 Drain Saddle 3 8 Kit 9 WP610109 4 Green 1 4 Tubing 10 WP610113 4 Blue 1 4 Tubing 11 WP400048 3 Black 3 8...

Страница 4: ...itting With the collet held in this position the tube can be removed The fitting can then be reused STEP 1 NOTICE Water supply line to the system must be from the cold water supply line only Hot water...

Страница 5: ...faucet may push up out of position Prior to the install hold the faucet as shown in the picture and pull down on the wing nut This will ensure that the O rings are in their proper position and that y...

Страница 6: ...ough one side of the drain pipe Step C The drain saddle must be installed at least 1 above the nut of the P Trap elbow or cross bar from the garbage disposal to insure proper drainage Using the 3 8 dr...

Страница 7: ...en so it can easily be closed to prevent water flowing to the ice maker during start up and periodic maintenance An Ice maker Connection Kit can be purchased through Premier Startup NOTICE If your RO...

Страница 8: ...conditions and the amount the RO system is used This reverse osmosis membrane is critical for effective reduction of total dissolved solids TDS The product water should be tested periodically to verif...

Страница 9: ...es then continue rinsing eye Call a poison control center or doctor for treatment advice Check Air Pressure in the Tank Procedure for Extended Non Use More than 2 months NOTICE Check air pressure only...

Страница 10: ...water Set tank air pressure between 5 7psi See previous page Low Pressure in Tank Use a Digital Air Gauge for best results The empty tank pressure should be 5 7psi See Page 9 4 Noise Water from faucet...

Страница 11: ...S Total Dissolved Solids not to exceed 1800 ppm DESCRIPTION PART CHANGE TIME FRAME Sediment Pre Filter WP105311 6 Months Carbon Pre Filter WP105351 6 Months Final Carbon Filter WP105341 12 Months 50 G...

Страница 12: ...7 43 50 psi 0 1 11 1 mg L 0 5 NTU Nitrate Nitrite N A N A 83 30 N A N A N A N A N A Recovery 25 5 Daily Production Rate 23 5 GPD Efficiency 12 8 This system has been tested according to NSF ANSI 58 fo...

Страница 13: ...senic may not con vert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is us...

Страница 14: ...cord DATE OF PURCHASE MODEL NUMBER SERIAL NUMBER DATE OF INSTALL INSTALLED BY INSTALLED BY DATE SEDIMENT 6 MONTHS PRE CARBON 6 MONTHS POST CARBON 1 YEAR RO MEMBRANE 2 5 YEARS IOM Premier RO PURE indd...

Страница 15: ...ions from abuse misuse misapplication improper maintenance neglect alteration accidents casualties fire flood freezing environmental factors water pressure spikes or other such acts of God This warran...

Страница 16: ...IOM Premier RO PURE indd 16 7 10 20 2 32 PM...