 Arsenic Facts 

Arsenic (As) is a naturally occurring contaminant found in many 

ground waters. Arsenic in water has no color, taste or odor. It must 

be measured by an arsenic test kit or lab test.
Public water utilities must have their water tested for arsenic. You 

can obtain the results from your water utility contained within your 

consumer confidence report. If you have your own well, you will need 

to have the water evaluated. The local health department or the  

state environmental health agency can provide a list of test kits  

or certified labs.
There are two forms of arsenic: pentavalent arsenic (also called As 

(V), As (+5)) and trivalent arsenic (also called As (III), As (+3)). In well 

water, arsenic may be pentavalent, trivalent, or a combination of 

both. Although both forms of arsenic are potentially hazardous to 

your health, trivalent arsenic is considered more harmful than pen-

tavalent arsenic. 
RO systems are very effective at removing pentavalent arsenic. A free 

chlorine residual will rapidly convert trivalent arsenic to pentavalent 

arsenic. Other water treatment chemicals such as ozone and potas-

sium permanganate will also change trivalent arsenic to pentavalent 

arsenic. A combined chlorine residual (also called chloramine) where 

it does convert trivalent arsenic to pentavalent arsenic, may not con-

vert all the trivalent arsenic in to pentavalent arsenic. If you get your 

water from a public water utility, contact the utility to find out if free 

chlorine or combined chlorine is used in the water system.
This reverse osmosis system is designed to remove up to 98% of 

pentavalent arsenic. It will not convert trivalent arsenic to pentavalent 

arsenic. Under laboratory standard testing conditions, this system 

reduced 0.30 mg/L (ppm) pentavalent arsenic to under 0.010 mg/L 

(ppm) (the USEPA standard for drinking water). Actual performance 

of the system may vary depending on specific water quality condi-

tions at the consumer’s installation. In addition to the independent 

laboratory standard testing conditions we have conducted additional 

field testing on our reverse osmosis units to determine trivalent 

arsenic reduction capabilities. Based upon field testing, it has been 

determined that the RO units are capable of reducing up to 67% of 

trivalent arsenic from the drinking water. 
This reverse osmosis system contains a replaceable component 

critical to the efficiency of the system, and for the removal of arsenic. 

Replacement of the reverse osmosis membrane should be with one 

of identical specifications, as defined by the manufacturer, to ensure 

the same efficiency and contaminant reduction performance. Specific 

RO membrane identification and ordering information can be found 

in the maintenance section of this manual.

IOM-Premier-RO-PURE.indd   13

7/10/20   2:32 PM

Содержание Premier RO-PURE

Страница 1: ...to a surface strong enough to support its weight System tested and certified by WQA against NSF ANSI Standard 58 for the reduction of the claims specified on the performance data sheet and to NSF ANSI...

Страница 2: ...ly reduced Stage 3 Membrane recommended change 2 5 years Stage three is the heart of the reverse osmosis system the 50GPD Gallons Per Day RO membrane This semi permeable membrane will effectively remo...

Страница 3: ...134018 1 4 QC x 1 4 FPT Tank Ball Valve 7 WP228173 Fitting 3 8 Stem x 1 4 QC Adapter 8 WP164056 Drain Saddle 3 8 Kit 9 WP610109 4 Green 1 4 Tubing 10 WP610113 4 Blue 1 4 Tubing 11 WP400048 3 Black 3 8...

Страница 4: ...itting With the collet held in this position the tube can be removed The fitting can then be reused STEP 1 NOTICE Water supply line to the system must be from the cold water supply line only Hot water...

Страница 5: ...faucet may push up out of position Prior to the install hold the faucet as shown in the picture and pull down on the wing nut This will ensure that the O rings are in their proper position and that y...

Страница 6: ...ough one side of the drain pipe Step C The drain saddle must be installed at least 1 above the nut of the P Trap elbow or cross bar from the garbage disposal to insure proper drainage Using the 3 8 dr...

Страница 7: ...en so it can easily be closed to prevent water flowing to the ice maker during start up and periodic maintenance An Ice maker Connection Kit can be purchased through Premier Startup NOTICE If your RO...

Страница 8: ...conditions and the amount the RO system is used This reverse osmosis membrane is critical for effective reduction of total dissolved solids TDS The product water should be tested periodically to verif...

Страница 9: ...es then continue rinsing eye Call a poison control center or doctor for treatment advice Check Air Pressure in the Tank Procedure for Extended Non Use More than 2 months NOTICE Check air pressure only...

Страница 10: ...water Set tank air pressure between 5 7psi See previous page Low Pressure in Tank Use a Digital Air Gauge for best results The empty tank pressure should be 5 7psi See Page 9 4 Noise Water from faucet...

Страница 11: ...S Total Dissolved Solids not to exceed 1800 ppm DESCRIPTION PART CHANGE TIME FRAME Sediment Pre Filter WP105311 6 Months Carbon Pre Filter WP105351 6 Months Final Carbon Filter WP105341 12 Months 50 G...

Страница 12: ...7 43 50 psi 0 1 11 1 mg L 0 5 NTU Nitrate Nitrite N A N A 83 30 N A N A N A N A N A Recovery 25 5 Daily Production Rate 23 5 GPD Efficiency 12 8 This system has been tested according to NSF ANSI 58 fo...

Страница 13: ...senic may not con vert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is us...

Страница 14: ...cord DATE OF PURCHASE MODEL NUMBER SERIAL NUMBER DATE OF INSTALL INSTALLED BY INSTALLED BY DATE SEDIMENT 6 MONTHS PRE CARBON 6 MONTHS POST CARBON 1 YEAR RO MEMBRANE 2 5 YEARS IOM Premier RO PURE indd...

Страница 15: ...ions from abuse misuse misapplication improper maintenance neglect alteration accidents casualties fire flood freezing environmental factors water pressure spikes or other such acts of God This warran...

Страница 16: ...IOM Premier RO PURE indd 16 7 10 20 2 32 PM...

Отзывы: