background image

Page 15

  

 

 

 

  

 

 

 

 

 

 

 

 

 

TROUBLE SHOOTING

Problem   

 Cause    Solution

1. Low/Slow Production  

Low Water Pressure 

 

Assure a minimum of 40 psi incoming water pressure.

 

 

 

 

 

 

 

Watts sells a booster pump if home water pressure is

 

 

 

 

 

 

 

low.  Make sure water supply is turned on and Adapta 

 

 

 

 

 

 

 

Valve is all the way open.

 

 

 

Crimps in tube   

 

Check tube and straighten or replace as necessary.

 

 

 

Clogged pre-filters 

 

Replace pre-filters.

 

 

 

Fouled membrane 

 

Replace membrane.

2. Milky colored Water   

Air in system   

 

Air in the system is a normal occurrence with initial  

 

 

 

 

 

 

 

 

start up of the RO system. This milky look will    

 

 

 

 

 

 

 

 

disappear during normal use within 1-2 weeks.  If  

 

 

 

 

 

 

 

 

condition reoccurs after filter change, drain tank 1 to 2    

 

 

     times.

3. Water constantly  

 

Low water pressure 

 

See #1 Above

    running, unit will not 

    shut off 

 

 

Crimp in supply tube 

 

Check tube and straighten or repair as necessary.

 

 

 

High water pressure 

 

Check incoming water pressure to make sure it does  

 

 

 

 

 

 

 

 

not exceed 80 psi.  A pressure relief valve may be  

 

 

 

     necessary.

 

 

 

High pressure in Tank   

Empty storage tank of water. Set tank air pressure  

 

 

 

 

 

 

 

 

between 5-7 psi. See previous page.

 

 

 

Low Pressure in Tank   

Use a Digital Air Gauge for best results.  The empty

 

 

 

 

 

 

 

tank pressure should be 5-7 psi. See page 14.

4. Noise / Water from faucet       Crimp or restriction 

 

Check tube and straighten or repair as necessary. 

    vent hole or noise from 

in drain line 

 

             Straighten all drain lines. Clear blockage.  Cut off any 

    drain. 

 

 

 

 

 

 

Excess tube

 

 

 

Drain tube clogged 

 

Caused from dishwasher or garbage disposal.

 

 

 

 

 

 

 

Disconnect the 3/8” black line at the drain, clean the  

 

 

 

 

 

 

 

 

3/8” black line out with a wire, then reconnect.  Blowing    

 

 

 

 

 

 

 

air through the line will not always remove the clog.

5. Small amount of water in 

System starting up 

 

Normally it takes 3-6 hours to fill tank.  Note: low  

           

    storage tank 

 

 

 

 

 

 

incoming water pressure and/or temperature can  

 

 

 

     drastically 

reduce 

production 

rate.

 

 

 

Low water pressure 

 

See #1 above.

 

 

 

To much air in tank 

 

Tank air pressure should be 5-7 psi when empty of water.

 

 

 

 

 

 

 

If below 5 psi add air or bleed if above 7 psi.

 

 

 

 

 

 

 

Check only when tank is empty of water.  

 

 

     See 

previous 

page.

6. Water leaks from the blue 

Not properly tightened   

Tighten the bowl.

    or white filter housing  

Kinked O-ring   

 

Turn off the water supply and release the pressure.

 

 

 

 

 

 

 

Replace the O-ring if necessary.  Then lubricate it and

 

 

 

 

 

 

 

make sure the O-ring is seated in the filter bowl    

 

 

 

 

 

 

 

 

properly before reinstalling the filter bowl.

7. Low water flow from faucet  Check air pressure in tank 

Use a Digital Air Gauge for best results.  The empty  

 

 

 

 

 

 

 

 

tank pressure should be 5-7 psi. See page 14.

Содержание GTS350C

Страница 1: ...ng Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Under the counter Reverse Osmosi...

Страница 2: ...ecommended change 6 months The first stage of your RO system is a five micron sediment filter that traps sediment and other particulate matter like dirt silt and rust which affect the taste and appear...

Страница 3: ...ect Fittings on Your RO System 7 Mount the Reverse Osmosis Faucet 8 Drain Saddle Installation 8 Red Tube Connection Drain Saddle 8 Green Tube Connection Feed Water 8 Blue Tube Connection RO System 9 T...

Страница 4: ...0 F 4 4 C Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness...

Страница 5: ...YELLOW TUBE BALL VALVE CHECK VALVE ELBOW FLOW RESTRICTOR ELBOW WHITE TUBE WHITE TUBE WHITE TUBE BLUE TUBE 1 4 DRAIN SADDLE RO FAUCET Pre Filter sediment FPMB5 978 Housing Lid FH4200WW14 Pre Filter car...

Страница 6: ...e porcelain to crack or chip Using a 1 diamond tip hole saw proceed to drill the large hole Keep drill speed on the slowest speed and use lubricating oil or liquid soap to keep the hole saw cool durin...

Страница 7: ...nect ensure the system is depressurized before removing the tube Push in the col lect squarely against face of fitting With the collet held in this position the tube can be removed The fitting can the...

Страница 8: ...you may use a small screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both...

Страница 9: ...to the Tee fitting attached to blue and white tubes slip the yellow tube through the white compression nut hand tighten the white nut and add 1 4 turn with a wrench Refer to diagram on page 5 Compres...

Страница 10: ...fourth tank can be used for drinking Open the RO faucet and leave it open until water begins to trickle out this may take a few minutes and the water will come out slowly Step 4 Turn on the incoming c...

Страница 11: ...ith water Check O rings and lubricate with water soluble lubricant KY Jelly or other water based lubricants may be used Petroleum based lubricants such as Vaseline must not be used Step 5 Before re in...

Страница 12: ...et and let the unit rest for 2 minutes Finally open the RO faucet and let the water run for 5 more minutes Turn off the incoming water supply to the system at the adapt a valve Keep the RO faucet open...

Страница 13: ...embrane when TDS reduction falls below 75 Step 1 Turn off the incoming water supply to the RO at the adapt a valve Open the RO Faucet and allow water to drain from the tank until it is completely empt...

Страница 14: ...n be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap Tip When water from the RO faucet slows to a trickle with the faucet s...

Страница 15: ...ssure should be 5 7 psi See page 14 4 Noise Water from faucet Crimp or restriction Check tube and straighten or repair as necessary vent hole or noise from in drain line Straighten all drain lines Cle...

Страница 16: ...ere is an average of 4 gallons of reject water for every 1 gallon of product water produced REFER TO OWNER S INSTALLATION SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION F...

Страница 17: ...valent arsenic A combined chlorine residual also called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not convert all the trivalent arsenic in to pentavalent arsenic If...

Страница 18: ...Page 18 Service Record Date of Purchase __________ Date of Install ___________ Installed by __________________ NOTES Date 1st stage Sediment 6 months 2nd stage Carbon 6 months TFM Membrane 2 3 years...

Страница 19: ...Page 19...

Страница 20: ...nd 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biol...

Отзывы: