Installation must comply with State and local plumbing regulations.  Do not use with water that is micro- 

biologically unsafe or of unknown quality without adequate disinfection before or after the system. 

System is intended to be installed using the cold water supply only. 

Tank 

 

    

   Faucet 

Box/Bag

Module – White (Filters Pre-Installed)    

Manual

Parts 

Bag 

 

    

Tools Recommended For Installation

√ 

1 1/4" Diamond Tipped Hole Saw bit for faucet opening (Counter Tops/Porcelain & Stainless Sinks)

√ 

1 1/4” Adjustable Wrench  

√ 

Phillips bit for electric drill

√ 

1/2" Open End Wrench   

√ 

Needle Nose Pliers

√ 

5/8” Open End Wrench   

√ 

Adjustable Pliers

√ 

Electric Drill 

 

 

√ 

Sharp Knife 

√ 

1/8" diamond tip bit, pilot hole 

√ 

Phillips Screw Driver

√ 

1/4” drain saddle hole   

Contents of the Reverse Osmosis (RO) System

Operating Temperatures:

Maximum 100°F (37.8°C)

Minimum 40°F (4.4°C)

Operating Pressure:

Maximum 100 psi (7.0 kg/cm

2

)

Minimum 40 psi (2.80 kg/cm

2

)

pH Parameters:

Maximum 11

Minimum 2

Iron:

Maximum 0.2 ppm

TDS (Total Dissolved Solids)

< 1800 ppm

Turbidity

< 5 NTU

Hardness

Maximum 10 Grains Per Gallon 

*

Hardness: 

Recommended hardness not to exceed 10 grains per gallon, or 170 parts per million.  

*  

System will operate with hardness over 10 grains but the membrane life may be shortened.    

 

   Addition of a water softener may lengthen the membrane life.

Copper Tube: 

Reverse Osmosis water should not be run through copper tube as  the purity of the 

water will leach copper causing an objectional taste in water and pin holes may form in the tube.

Water Pressure: 

The operating water pressure in your home should be tested over a 24 hour 

period to attain the maximum pressure.  If the incoming water pressure is above 100 psi then a 

water pressure regulator is required. A booster pump is needed for incoming water pressure 

under 40psi.

Operational Parameters

INSTALLATION & STARTUP

INSTALLATION & STARTUP

Содержание GTS350C

Страница 1: ...ng Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Under the counter Reverse Osmosi...

Страница 2: ...ecommended change 6 months The first stage of your RO system is a five micron sediment filter that traps sediment and other particulate matter like dirt silt and rust which affect the taste and appear...

Страница 3: ...ect Fittings on Your RO System 7 Mount the Reverse Osmosis Faucet 8 Drain Saddle Installation 8 Red Tube Connection Drain Saddle 8 Green Tube Connection Feed Water 8 Blue Tube Connection RO System 9 T...

Страница 4: ...0 F 4 4 C Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness...

Страница 5: ...YELLOW TUBE BALL VALVE CHECK VALVE ELBOW FLOW RESTRICTOR ELBOW WHITE TUBE WHITE TUBE WHITE TUBE BLUE TUBE 1 4 DRAIN SADDLE RO FAUCET Pre Filter sediment FPMB5 978 Housing Lid FH4200WW14 Pre Filter car...

Страница 6: ...e porcelain to crack or chip Using a 1 diamond tip hole saw proceed to drill the large hole Keep drill speed on the slowest speed and use lubricating oil or liquid soap to keep the hole saw cool durin...

Страница 7: ...nect ensure the system is depressurized before removing the tube Push in the col lect squarely against face of fitting With the collet held in this position the tube can be removed The fitting can the...

Страница 8: ...you may use a small screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both...

Страница 9: ...to the Tee fitting attached to blue and white tubes slip the yellow tube through the white compression nut hand tighten the white nut and add 1 4 turn with a wrench Refer to diagram on page 5 Compres...

Страница 10: ...fourth tank can be used for drinking Open the RO faucet and leave it open until water begins to trickle out this may take a few minutes and the water will come out slowly Step 4 Turn on the incoming c...

Страница 11: ...ith water Check O rings and lubricate with water soluble lubricant KY Jelly or other water based lubricants may be used Petroleum based lubricants such as Vaseline must not be used Step 5 Before re in...

Страница 12: ...et and let the unit rest for 2 minutes Finally open the RO faucet and let the water run for 5 more minutes Turn off the incoming water supply to the system at the adapt a valve Keep the RO faucet open...

Страница 13: ...embrane when TDS reduction falls below 75 Step 1 Turn off the incoming water supply to the RO at the adapt a valve Open the RO Faucet and allow water to drain from the tank until it is completely empt...

Страница 14: ...n be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap Tip When water from the RO faucet slows to a trickle with the faucet s...

Страница 15: ...ssure should be 5 7 psi See page 14 4 Noise Water from faucet Crimp or restriction Check tube and straighten or repair as necessary vent hole or noise from in drain line Straighten all drain lines Cle...

Страница 16: ...ere is an average of 4 gallons of reject water for every 1 gallon of product water produced REFER TO OWNER S INSTALLATION SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION F...

Страница 17: ...valent arsenic A combined chlorine residual also called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not convert all the trivalent arsenic in to pentavalent arsenic If...

Страница 18: ...Page 18 Service Record Date of Purchase __________ Date of Install ___________ Installed by __________________ NOTES Date 1st stage Sediment 6 months 2nd stage Carbon 6 months TFM Membrane 2 3 years...

Страница 19: ...Page 19...

Страница 20: ...nd 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biol...

Отзывы: