Start up Instructions

If you have connected your RO system to a refrigerator / ice maker, make sure the ice maker is 

off (do not allow water to flow to the ice maker) until flushing (Step 4) is complete and the tank 

has been allowed to fill completely. Connection from the RO to the ice maker system should 

have an in-line valve installed before the ice maker so it can easily be closed to prevent water 

flowing to the ice maker during start up and periodic maintenance. Your storage tank must be 

allowed to fill up fully in order for the ice maker system to work properly. 

After the storage tank has filled (the water trickling has stopped), open the RO Faucet to 

flush the tank completely. You will know that the tank is empty when the flow rate from the 

RO faucet is down to a trickle.  Repeat this step two more times.  The fourth tank can be 

used for drinking. 

Open the RO faucet and leave it open until water begins to trickle out (this may take a few 

minutes and the water will come out slowly).

Step 4

Turn on the incoming cold water at the angle stop valve and the 

Adapt-a-Valve. Check the system for leaks and tighten any fittings 

as necessary.   (Check frequently over the next 24 hours to ensure 

no leaks are present).

Step 3

Step 2

Note:

Step 1

Close the RO faucet allowing the storage tank to fill with water.  It may take 3 to 6 hours to 

fill the tank completely depending on the production capability of the membrane, local water 

temperature and water pressure. 

Flushing of the tank 3 times is only necessary during the initial startup and after replacing the 

membrane.

During the fill period you may hear water trickling which is a normal occurrence.

Note:

Note:

Congratulations!

You have completed the installation of new your Reverse Osmosis system.

Please Follow the Startup Instructions.

The flushing process should take about a day to complete. 

ON

Содержание GTS350C

Страница 1: ...ng Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Under the counter Reverse Osmosi...

Страница 2: ...ecommended change 6 months The first stage of your RO system is a five micron sediment filter that traps sediment and other particulate matter like dirt silt and rust which affect the taste and appear...

Страница 3: ...ect Fittings on Your RO System 7 Mount the Reverse Osmosis Faucet 8 Drain Saddle Installation 8 Red Tube Connection Drain Saddle 8 Green Tube Connection Feed Water 8 Blue Tube Connection RO System 9 T...

Страница 4: ...0 F 4 4 C Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness...

Страница 5: ...YELLOW TUBE BALL VALVE CHECK VALVE ELBOW FLOW RESTRICTOR ELBOW WHITE TUBE WHITE TUBE WHITE TUBE BLUE TUBE 1 4 DRAIN SADDLE RO FAUCET Pre Filter sediment FPMB5 978 Housing Lid FH4200WW14 Pre Filter car...

Страница 6: ...e porcelain to crack or chip Using a 1 diamond tip hole saw proceed to drill the large hole Keep drill speed on the slowest speed and use lubricating oil or liquid soap to keep the hole saw cool durin...

Страница 7: ...nect ensure the system is depressurized before removing the tube Push in the col lect squarely against face of fitting With the collet held in this position the tube can be removed The fitting can the...

Страница 8: ...you may use a small screwdriver to feed through the drain saddle into the drain pipe to aid with the alignment Using a Phillips screw driver tighten the drain saddle bolts evenly and securely on both...

Страница 9: ...to the Tee fitting attached to blue and white tubes slip the yellow tube through the white compression nut hand tighten the white nut and add 1 4 turn with a wrench Refer to diagram on page 5 Compres...

Страница 10: ...fourth tank can be used for drinking Open the RO faucet and leave it open until water begins to trickle out this may take a few minutes and the water will come out slowly Step 4 Turn on the incoming c...

Страница 11: ...ith water Check O rings and lubricate with water soluble lubricant KY Jelly or other water based lubricants may be used Petroleum based lubricants such as Vaseline must not be used Step 5 Before re in...

Страница 12: ...et and let the unit rest for 2 minutes Finally open the RO faucet and let the water run for 5 more minutes Turn off the incoming water supply to the system at the adapt a valve Keep the RO faucet open...

Страница 13: ...embrane when TDS reduction falls below 75 Step 1 Turn off the incoming water supply to the RO at the adapt a valve Open the RO Faucet and allow water to drain from the tank until it is completely empt...

Страница 14: ...n be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap Tip When water from the RO faucet slows to a trickle with the faucet s...

Страница 15: ...ssure should be 5 7 psi See page 14 4 Noise Water from faucet Crimp or restriction Check tube and straighten or repair as necessary vent hole or noise from in drain line Straighten all drain lines Cle...

Страница 16: ...ere is an average of 4 gallons of reject water for every 1 gallon of product water produced REFER TO OWNER S INSTALLATION SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION F...

Страница 17: ...valent arsenic A combined chlorine residual also called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not convert all the trivalent arsenic in to pentavalent arsenic If...

Страница 18: ...Page 18 Service Record Date of Purchase __________ Date of Install ___________ Installed by __________________ NOTES Date 1st stage Sediment 6 months 2nd stage Carbon 6 months TFM Membrane 2 3 years...

Страница 19: ...Page 19...

Страница 20: ...nd 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biol...

Отзывы: