Explanation of Function
Seite 105 / 180
Free-run stop (FRS)
By operating the free-run stop (FRS) function, the inverter output is cut off.
The motor will free wheel under its own momentum.
This function is used when the motor is to be stopped by the use of a
brake, like an electromagnetic brake.
If you stop the motor with a machine brake while the inverter is still
Outputting to the motor an over-current trip may occur.
Assign 11(FRS) to an intelligent input terminal.
This free-run stop function will operate when the FRS terminal is ON.
If you turn FRS terminal OFF the inverter will restart after the retry wait time b003 passes.
However when the operation command selection A002 is set to control terminal (01), the inverter restarts
during free-running.
This function will only operate when the FW terminal is ON.
On restart it is possible to select 0Hz start or matching frequency start as output methods with the free-run
stop selection b088. (Example 1, 2)
When you set the frequency setting to match (b007) and the frequency detected is under this setting when
the free-run stop is released, the inverter is restarted from 0Hz.
The setting of this function is valid for selection b091 on stopping and reset (RS) action.
Set item
Function
code
Data Description
00
0Hz start (example 1)
Free-run stop
Selection
b088
01
Equaling frequency start (example 2)
Retry wait time
b003
0.3-100. Units:second
Time until restart after FRS terminal is OFF.
(This is also used for Instantaneous restart.)
Frequency setting to
match
b007 0.00-400.0
Units:Hz (instantaneous stop, reference to
item
of insufficiency)
This sets the level to match frequency.
(Refer to item of instantaneous stop and
restart.)
b088 : Free-run stop selection
b003
: Retry wait time
b007
: frequency setting to
match
Relation code
FW
FRS
The number of
0
Free-run
0Hz start
(Example1) 0Hz start
FW
FRS
The number of
t
l ti
ti0
Free-run
Start equaling
(Example2)
Equaling
t t
b003
Содержание V3000-015LF
Страница 1: ...INVERTER Series V3000 M A N U A L...
Страница 13: ...General Descriptions Seite 13 180 6 2 Dimension 178...
Страница 91: ...Explanation of Function Seite 91 180 Reduced rated ratio Inverter output Frequency X1 0 0 60 X0 9 X0 8 5 2 5...
Страница 173: ...Explanation of Function Seite 173 180 RB N No conduct N RB No conduct...
Страница 179: ...Specification Seite 179 180 V3000 150 220NF HF V3000 300NF HF 2 31 26 54 51 10 19 25 22 2 39 37 7 22 9 24 19 92...
Страница 180: ...Specification Seite 180 180 V3000 370 450NF HF V3000 550NF HF 25 55 52 10 39 30 2 25 70 67 12 48 38 2...