20.4
Assigning the PROFIBUS station address at the pump
The station address can only be set from PROFIBUS settings. The station address cannot be automatically
assigned by the master.
Select
MODE
.
Use the
∧
and
∨
keys to scroll to
PROFIBUS
and press
SETTINGS
.
Use the
∧
and
∨
keys to alter the station address, in the range from 1 to 125 (126 is the default station
address). Press
FINISH
to set the station address, or
NEXT
to enable/disable PROFIBUS communication.