IP66 Wiring - N Module
Never apply mains power to the M12 connectors. Apply the correct signals to
the terminals. Limit signals to the maximum values shown. Do not apply
voltage across other terminals. Permanent damage, not covered by warranty,
may result. The maximum rating on the relay contacts of this pump is 30V DC;
maximum load 30W.
Note: Also suitable for low power: ie, 1mA at 5V DC minimum.
The recommended cable and cable glands must be used for the IP66 (NEMA
4X) version of the pump; otherwise ingress protection may be impaired.
Ensure that the module cover is correctly secured at all times by all screws
supplied. Failure to do so may compromise the IP66 (NEMA 4X) protection.
Ensure that unused openings on the module are sealed using the blanking
plugs provided. Failure to do so may compromise the IP66 (NEMA 4X)
protection.