Use
NEXT
to move the selection bar to the next setting.
Use
+/-
to alter the value of the highlighted setting:
l
The
contact dose
is the volume of fluid the pump will dispense when an external pulse
is received on input pin 2.
l
The
flow rate
will determine the time taken to complete each dose.
l
Contact memory
determines what the pump will do when pulses are received while a
dose is in progress. If set to “ignore” the pulses will be forgotten by the pump. If set to
“add” any pulses received while dosing will be queued up in memory and will be
dispensed when the current dose has finished.
If pulses are buffered in the memory then the pump will not stop between doses.
Once you have decided all your settings press
FINISH
and press
SAVE
to store.
Figure 23 - Electrical pulse specification
T
t
t
2
Vmax
V
0
V:
Voltage
T:
Time
Vmax:
Maximum voltage
t:
40 ms (min) to
1000 ms (max)
Vmin:
> 1.9 V
t
2:
> 1 s
m-qdos-allmodels-en-07
94