This product does not comply with the ATEX directive and must not be
used in explosive atmospheres.
The pump must be bolted to a flat, horizontal, rigid surface, free from
excessive vibration, to ensure correct lubrication of the gearbox and
correct pumphead operation. Allow a free flow of air around the pump
to ensure that heat can be dissipated. Ensure that the ambient
temperature around the pump does not exceed 45 °C (113 °F).
If pumping flammable liquids, a full risk assessment should be
completed prior to use.
The exterior surfaces of the pump may get hot during operation. Do
not take hold of the pump while it is running. Allow the pump to cool
after use before handling. The drive unit must not be run without a
pumphead fitted. The pumphead should not be run dry for extended
periods of time. The pump should not be used to pump fluids where
the temperature of the fluid can reach temperatures of more than
70 °C.
Ensure the chemicals to be pumped are compatible with the
pumphead, lubricant, tubing, pipework and fittings to be used with
the pump. Please refer to the chemical compatibility guide which can
be found at: www.wmftg.com/gb-en/range/watson-marlow/chemical-
metering/. If you need to use the pump with any other chemical
please contact Watson-Marlow to confirm compatibility
m-qdos-allmodels-en-07