Release
RECOVER
to stop running the pump in reverse.
23.4
Remote fluid recovery (Universal and Un models
without relay modules)
It is possible to run the pump in reverse and recover fluid automatically in the analog
4-20 mA mode. To achieve this, it is necessary to enable remote fluid recovery
functionality. To enable this position the selection bar over fluid recovery in the mode
menu and press the
SETTINGS
function key.
Select
ENABLE
to turn this functionality on. The reverse process can be used to switch the
function off.
When this function is enabled, the pump operation can be reversed in analog 4-20 mA
mode by applying minimum 5 V to maximum 24 V to pin 5 of the pump input. The pump will
operate at a reversed set speed proportional to the 4-20 mA input applied to pin 3.
m-qdos-allmodels-en-07