dispenser with maximum calibration to 3 bar.
Danger
a filtration system placed upstream of the dispenser requires
a different procedure of work start. The water entering into the
dispenser should be particulate-free and clear (no suspended
elements).
Light waters (like the ones coming from osmosis) can alter CO₂
effervescence.
Before opening the main water valve, follow the indications given in
section "Connection and duty start".
Connection with power supply
The connection with power supply is provided connected the IEC cable
with a power socket. This power socket must be connected to ground and
suitable for dispenser requirements (see technical sheet).
Check that line voltage meets the technical features it should respect.
Connect the female plug IEC 320 in the specific socket of the dispenser.
Connect the male plug of the cable to power supply socket.
Warning
replace immediately the power cable if damaged
Before turning the dispenser ON, follow the indications given in section
"Connection and duty start".
Connection with CO₂ cylinder
1. Connect the pressure regulator R with CO₂
cylinder B checking the correct position of
Teflon gasket.
2. Tighten the nut N and check that tubing T
(outlet) is connected properly
3. CO₂ cylinder must be kept in upright
position
4. CO₂ cylinder must be secured with a chain or
similar to avoid falling
14
T
R
N
B
G
Содержание WatHome20 Series
Страница 1: ...Overcounter and undercounter water coolers WatHome20 Instruction manual WatHome20Up WatHome20In...
Страница 31: ......