20
Malfunctioning, causes, seek-out, interventions
Malfunctioning
Probable cause
Suggested intervention
Dispenser will not switch
on
Dispenser works but will
not produce cold
Water carbonation is scarce
or very low
Compressor works but will
not produce cold
Compressor and vent work
but the pump never stops
Compressor is still but the
vent turns and works
Carbonator pump is noisy
• Loss of refrigerating
gas
• Obstructed or soiled
condenser
• Scarce CO₂ pressure
• Too much air gathered
in carbonator
• No power supply on
vent
• Obstructed or soiled
condenser
• Vent is damaged
• Damaged thermostat
• Clixon thermal protector
of compressor is
activated
• Damaged compressor
• Damaged condenser
• Very low water pressure
inlet
• Call specialized
professional
• Clean throughout the
condenser with a brush
or with air blow
• Replace CO₂ bottle if
empty
• Briefly discharge the
saturator pulling the ring
placed on top on
discharge valve
• Call specialized
professional
• Call specialized
professional
• Call specialized
professional
• Call specialized
professional
• Call specialized
professional
• Call specialized
professional
• Call specialized
professional
• Check water supply
pressure
• No power supply
• Burnt fuse
• Check for damages on
power supply plant
and cables
Содержание WatHome20 Series