background image

 

 

 

Issue: 2011-01-04

 

 

 

 

 

 

 

 

 

 

 

 

Dispensers

 

 

 

Pipe dispensers R … 

••

 

round, RR … 

••

 

square, RE … 

Exchange dispensers WE … 

Platform dispensers P … 

••

 

open, PO … 

••

 

closed, PG … 

••

 

circulating air-heated, PU … 

Ultra dispenser REU … 

Built-in dispensers ERR …

 

 

Original user guide  

RR …

 

 

PO …

 

 

ERR …

 

ERR …

 

Summary of Contents for ERR Series

Page 1: ...4 Dispensers Pipe dispensers R round RR square RE Exchange dispensers WE Platform dispensers P open PO closed PG circulating air heated PU Ultra dispenser REU Built in dispensers ERR Original user guide RR PO ERR ERR ...

Page 2: ...ciples 13 5 2 On use of electrical appliances 13 5 3 Operator s duties 15 5 4 Personnel qualification 15 5 5 Provide protective equipment for personnel 16 5 6 Appliance specific safety instructions 16 5 7 Information about regulations to be followed 17 5 8 What to do in an emergency 17 6 Before first use 18 6 1 Transport 18 6 2 Commissioning 18 7 Adjust the dispenser to the crockery used 19 7 1 Pi...

Page 3: ...Contents Rieber GmbH Co KG 3 10 Fault What now 29 11 Warranty and liability 31 12 Address of manufacturer 32 ...

Page 4: ... product It is essential that you read the user guide before using the product for the first time Keep this guide in a safe place and pass it onto the next owner should you wish to part with the product Customers have often expressed their desire for a compact manual as an alternative to numerous instructions for product variants with similar functions If there are any deficits from your point of ...

Page 5: ...mation or tip 2 3 Structure of safety instructions The signal words DANGER WARNING CAUTION classify the possible degree of risk of bodily injury in an actual situation Injuries can be prevented provided that the relevant instructions are followed The warning triangle symbol indicates a General Danger DANGER indicates imminent danger Failure to follow these warning instructions will result in serio...

Page 6: ...justment of uniform serving height by connecting and hanging out the tension springs 4 corner bumpers Galvanized casters in accordance with DIN 18867 part 8 Wheel diameter 125 mm 2 swivel casters and 2 swivel casters with brakes anti static tires Electrical unit equipped with pull out spiral cable 2 5 m with earthed connector and dummy socket outlet rocker ON OFF switch with green indicator lamp t...

Page 7: ...ckable parts WARNING Wear personal protective equipment such as protective gloves which will prevent you from burning your arms or hands on hot parts such as plates meal trays etc The unit may only be used by instructed persons minimum age 16 years Comply with hygiene requirements according to HACCP Prevent any potential misuse in advance WARNING Never operate the product unsupervised CAUTION Bask...

Page 8: ...nd parts Type identification R R Pipe dispensers R R round R R V 1 with 1x adjustable pipe unheated R R V with adjustable pipe Desired plate diameter can be fixed by means of 3 adjustable rods R R H heated static heating R R U heated circulating air fan heating R R 1 number of pipes R R L provided with ventilation slots For pre cooling plates etc in cold or freezer rooms With RRV 190 280 from Ø 19...

Page 9: ...uare R H heated static heating R U heated circulating air fan heating R 2 number of pipes 4 3 Use of exchange dispensers WE Generally the following are intended uses for the product 6 change rods can be installed as required in 18 holes Adjustable for crockery parts of different sizes Max load capacity 150 kg REH 2 WE H R WE Q 1 1 R ...

Page 10: ...ndles with bumper 2 corner bumpers 4 4 Use of platform dispensers PO Generally the following are intended uses for the product For stacking and dispensing of trays or crockery baskets Max load capacity 200 kg 4 4 1 Platform dispensers open PO Type identification PO Platform dispenser open PO SV Food distribution PO GN Gastronorm PO Q square PO SV1 1 Special design with side tray guide for tray sta...

Page 11: ...G 4S for 4 cloches per level PG 6S for 6 cloches per level PK Q1 1 circulating air cooled 4 4 3 Platform dispensers circulating air heated and meal tray dispenser circulating air heated PU Type identification PU Platform dispenser circulating air heated PU GN Gastronorm PU SV food distribution PU Q square PU M stainless steel hinged lid only suitable for stainless steel baskets PU M R ...

Page 12: ...ication REU Ultra dispenser REU P for heating up heat ultra bowls 4 6 Use of built in dispensers ERR Generally the following are intended uses for the product Unheated or heated pipe dispensers are designed for stationary installation in a counter or serving system Type identification ERR Built in dispenser ERR V adjustable pipe unheated ERR V H adjustable pipe static heating REU P R ERR V H R ERR...

Page 13: ... shock Avoid bodily contact with earthed surfaces such as pipes heating units cookers and refrigerators The risk of an electric shock is greater when your body is earthed Keep the appliance away from rain or damp Allowing water to get into an electric appliance will increase the risk of electric shock Do not misuse the cable by using it to remove the plug from the socket Always remove whilst holdi...

Page 14: ...g parts of the appliance work perfectly and are not jammed also check whether any parts are broken or damaged to the extent that operation of the appliance is impaired Have any damaged parts repaired before using the appliance Many accidents are caused by poorly maintained electrical appliances Use electrical appliances accessories etc in accordance with these guidelines and in a manner that is sp...

Page 15: ...stood this guide In addition the operator must train the personnel and inform them of the hazards involved at regular intervals The operator must provide the personnel with the necessary protective equipment and make sure that they wear it In addition the operator must ensure that the machine is always in a perfect technical condition For this reason the following shall apply The operator must ens...

Page 16: ... you install a earth leakage circuit breaker with a tripping current of 30 mA upstream to the appliance 5 6 2 Hazards by mechanically blocked parts shooting up WARNING There are various hazards risk of injury in the dispenser platform area of pipe dispenser R exchange dispensers WE built in dispensers E The platform may get stuck if crockery or pieces of broken pieces are caught between the spring...

Page 17: ...m height of a level is 4 mm 5 7 Information about regulations to be followed Alongside this user guide there are a range of health and safety and other regulations that are relevant for the operation of this cooking station these include HACCP food hygiene regulations for example 5 8 What to do in an emergency In an emergency always turn the main switch off First aid in the case of bruises cuts bu...

Page 18: ...sport packaging at the positions provided for this purpose Do not tear or cut Check scope of delivery using the dispatch note Remove any protective foils from the inside and the outside of the appliance 6 1 3 Dispose of packaging material Dispose of packaging material in a proper and environmentally compatible manner 6 1 4 Clean the appliance Clean the appliance thoroughly before using for the fir...

Page 19: ...round RR to crockery diameter Apply parking brake and unplug mains plug Take out dispenser pipe 3 Using a tool loosen the spring clip 2 Lift up adjustment rod 1 and move as required Fix adjustment rod 1 in bottom hole 4 All adjustment rods must be fixed in the corresponding hole Between the adjustment rods 1 and plates there should be a continuous gap of 2 to 5 mm in order to compensate for crocke...

Page 20: ... operation Carry out the setup work correctly The springs are provided with an open eye on the one side and a closed eye on the other side When installing the springs ensure that the open side always faces up See illustration at beginning Place the empty pipe on a level surface Put approx 20 plates into the pipe Spring adjustment is ideal if approx 3 to 6 plates project over the edge of the pipe I...

Page 21: ...pe The dispenser platform can be divided 6 change rods can be installed in 18 holes The holes are distributed in accordance with the most common plate diameters 200 220 240 260 280 mm Adjustment of exchange dispenser to crockery Apply parking brake and unplug mains plug Take out dispenser pipe 3 Fix change rods 1 Between the change rods 1 and plates there should be a continuous gap of 2 to 5 mm in...

Page 22: ...ling the springs ensure that the open side always faces up Otherwise the springs may loosen during operation Carry out the setup work correctly Ensure that the open side of the spring always faces up See illustration at beginning Place the empty pipe on a level surface Put approx 20 plates into the pipe Spring adjustment is ideal if approx 3 to 6 plates project over the edge of the pipe If more pl...

Page 23: ...dispensing level is below lower edge of casing Fingers and hands may get caught Ensure that the dispensing level is always above the lower edge of the casing 7 3 Platform dispenser PO 1 hexagon socket screw 2 suspended spring 3 removed spring Apply parking brake and unplug mains plug 1 2 3 ...

Page 24: ...form Spring adjustment is perfect if the top basket is flush with the edge or a little below If platform projects remove the springs again If platform does not project enough install springs Close the casing and or the separating facility again To that end tighten the hexagon socket screw 1 firmly WARNING Risk of injury if dispensing level is below lower edge of casing Fingers and hands may get ca...

Page 25: ...use of the product in public for self service should only be allowed under constant supervision Comply with hygiene requirements according to HACCP WARNING Only remove the parts at serving height Jammed parts may generate high forces which may unload suddenly Stacked parts must be centred and guided WARNING Wear personal protective equipment such as protective gloves which will prevent you from bu...

Page 26: ...aged in hot dispensers and might also damage the appliance This also applies to plastic baskets with typical dishwasher quality Do not use baskets made of plastic for heated crockery dispensers Fill the dispenser with crockery evenly Finally close it with the lid Turning the unit on and heating cooling Plug in the connecting plug Press the rocker switch with the green indicator The product is oper...

Page 27: ...ms on the hot surfaces around the hot cooking modules Where possible wear protective gloves Allow appliance to cool down Keep unauthorised persons away from the product Never operate the product unsupervised 9 2 Avoid dangers due to electricity DANGER Danger of electric shock Risk of death Disconnect appliance from mains power Never direct a jet of water at electrical components such as heater con...

Page 28: ...decolouration of the surfaces and even corrosion Do not use any steel wool or steel brushes 9 4 Clean and service stainless steel parts NOTE Improper cleaning can cause damage to the surface Clean the appliance with a mild detergent diluted in hot water After cleaning rub surfaces dry with a soft cloth User tip We recommend Rieber cleaning agent for stainless steel for cleaning stainless steel Is ...

Page 29: ...t before starting repair work Have all electrical repairs carried out by an authorised electrician only Fault Possible cause Possible remedy Indicator lamp not on Device not connected correctly Check connection connectors User No power supply Check existing fuse Qualified electrician Temperature not controllable Temperature controller defective Repair Qualified electrician Appliance has overheated...

Page 30: ...o much Spring force too low Install springs User See page 19 Crockery is not moved up Platform stuck Crockery got stuck in springs Platform got stuck Remove crockery carefully piece by piece WARNING Prevent the platform from shooting up by means of a stable rod If necessary cut springs through individually to reduce the spring force Check pipe for mechanical damage call service if necessary Replac...

Page 31: ... plug Cut off the cable directly at the casing Dispose of this product properly via your local disposal facility 11 Warranty and liability Manufacturer liability and warranty shall no longer apply if the information and instructions in this user guide were not followed the product was not used as per the specifications See chapter Intended use conversions or functional modifications were made non ...

Page 32: ...s of manufacturer 32 Rieber GmbH Co KG 12 Address of manufacturer Rieber GmbH Co KG Hoffmannstraße 44 D 72770 Reutlingen Germany Phone 49 0 7121 518 0 FAX 49 0 7121 518 302 Email info rieber de www rieber de ...