Watlow PM PLUS™ 6
• 70 •
Chapter 6: Profiles
• jump
• end
• time
3. Press the left back arrow to return to the
Step Type 1
List. You'll note new parameters available, as ap-
plicable to the Step Type selected.
4. Select the newly available parameters for the selected Step Type. In this example with Time as the first
Step Type, you'll see
Hours, Minutes, Seconds
in the List now. Select each of these and set the number of
hours, minutes, or seconds required for Step 1.
5. Press the left back arrow to return to the Profile 1 List of steps, then repeat steps 2 and 3 for each of the
Profile Steps.
Starting a Profile
There are three ways to start a profile:
• Configure the Function Key to start a profile
• Configure a Digital Input to start a profile (check the configuration of your control to confirm that you
have a DIO option)
• Manually start a profile from the Operations — Profile.
Configuring the Function Key to Start and Stop a Profile
1. Navigate to the
Operations — Setup -Function Key
.
2. Select Action Function.
3. Select either
Start Profile
or
Profile Start/Stop
.
• With Start Profile, the function key will start a profile only.
• With Profile Start/Stop, one press of the function key starts the selected profile and the next press stops it.
4. Press Left Back Arrow to return to the Function Key List and select
Function Instance
5. Use the numeric slider or +/- keys to select the Profile
6. Return to the Home Screen by pressing the home icon.
Configuring a Digital Input to Start and Stop a Profile
1. Navigate to
Operations — Setup - Digital I/O
menu.
2. Select either Digital I/O 5.
3. Select the Input type - Voltage or Dry Contact.
4. Select Action Function.
5. Select either
Start Profile
or
Profile Start/Stop
.