![Watlow PM PLUS 6 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/watlow/pm-plus-6/pm-plus-6_user-manual_3806302017.webp)
Watlow PM PLUS™ 6
• 17 •
Chapter 2: Installation
Chapter 2: Installation
Installing the Device
1. Make the panel cutout using the measurements shown here. We recommend a minimum of 21.6 mm
between panel cutouts.
2. Remove the green terminal connectors and the mounting collar assembly.
3. Insert the controller into the panel cutout from the front.
4. Orient the collar base so the flat side faces front and the screw openings are on the sides, then slide the base
over the back of the controller.
5. Slide the mounting bracket over the controller with the screws aligned to the collar base.
6. Push the bracket gently but firmly until the hooks snap into the slots in the case.
7. Tighten the two #6-19 x 1.5" screws with a Phillips screwdriver until the device is flush to the panel
(3 to 4 in-lbs torque).
8. Secure screws from the back with Philips screwdriver.
Reinstall the terminal connectors to their original locations. (Or first connect field wiring as indicated in this
guide and then reinstall the connectors).
n/a
n/a
PM6 Refresh Layout
Pape 4-15-2019
D
C
B
A
A
B
C
D
MATERIAL
SHT
1
OF
1
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
SCALE
PART NO.
DWN
TITLE
MFG
ENG
PRCH
FINISH
WATLOW OF WINONA, MINNESOTA, CLAIMS PROPRIETARY RIGHTS TO THE MATERIAL HEREIN DISCLOSED.
IT IS SUPPLIED IN CONFIDENCE, WITHOUT PREJUDICE TO ANY PATENT RIGHTS OF WATLOW ELECTRIC, AND MAY NOT
BE REPRODUCED OR USED TO MANUFACTURE ANYTHING SHOWN THEREIN WITHOUT WATLOW'S WRITTEN PERMISSION.
NOTICE TO PERSONS RECEIVING THIS DRAWING
1241 BUNDY BLVD., P.O. BOX 5580
WINONA, MN 55987-5580
www.watlow.com
PM6 Final
1:1
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS AND TOLERANCING ARE IN INCHES
AND PER ANSI Y14.5M
TOLERANCES:
X.X ā 0.015
X.XX ā 0.010
X.XXX ā 0.005
ANGLES
ā 2 Ā
THIRD ANGLE
PROJECTION
TITLE BLOCK: temp_b, Rev D
REVISION
REV.
DESCRIPTION
DATE
ECO
1
PROTO
XX/XX/20XX
-
2 Updated
5/31/2019
--
2.10 in.
(53.3 mm)
2.10 in.
(53.3 mm)
Mounting Panel
4.164 in.
(105.8 mm)
0.4 in.
(10.2 mm)
n/a
n/a
PM6 Refresh Layout
Pape 4-15-2019
D
C
B
A
A
B
C
D
MATERIAL
SHT
1
OF
1
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
SCALE
PART NO.
DWN
TITLE
MFG
ENG
PRCH
FINISH
WATLOW OF WINONA, MINNESOTA, CLAIMS PROPRIETARY RIGHTS TO THE MATERIAL HEREIN DISCLOSED.
IT IS SUPPLIED IN CONFIDENCE, WITHOUT PREJUDICE TO ANY PATENT RIGHTS OF WATLOW ELECTRIC, AND MAY NOT
BE REPRODUCED OR USED TO MANUFACTURE ANYTHING SHOWN THEREIN WITHOUT WATLOW'S WRITTEN PERMISSION.
NOTICE TO PERSONS RECEIVING THIS DRAWING
1241 BUNDY BLVD., P.O. BOX 5580
WINONA, MN 55987-5580
www.watlow.com
PM6 Final
1:1
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS AND TOLERANCING ARE IN INCHES
AND PER ANSI Y14.5M
TOLERANCES:
X.X ā 0.015
X.XX ā 0.010
X.XXX ā 0.005
ANGLES
ā 2 Ā
THIRD ANGLE
PROJECTION
TITLE BLOCK: temp_b, Rev D
REVISION
REV.
DESCRIPTION
DATE
ECO
1
PROTO
XX/XX/20XX
-
2 Updated
5/31/2019
--
2.10 in.
(53.3 mm)
2.10 in.
(53.3 mm)
Mounting Panel
4.164 in.
(105.8 mm)
0.4 in.
(10.2 mm)
• This equipment is suitable for use in Class 1, Div. 2, Groups A, B, C
and D or Non-Hazardous locations only. Temperature Code T4A.
Note:
Class 1, Div 2 is only valid if the last 2 characters in the part # are "12".
• EXPLOSION HAZARD. Substitution of component may impair
suitability for Class 1, Div. 2.
• EXPLOSION HAZARD. Do not disconnect equipment unless power has
been switched off or the area is known to be nonhazardous.
Содержание PM PLUS 6
Страница 134: ...Watlow PM PLUS 6 134 Chapter 10 Appendix...
Страница 135: ...Watlow PM PLUS 6 135 Chapter 10 Appendix...