Line
Function
Setting range
or display
Setting
increment
Basic
setting
Diagnostics consumers
8700
U
Outside temperature
-50... 50 °C
--
8701
U
Outside temp min
Reset ? (no, yes)
-50... 50 °C
--
8702
U
Outside temp max
Reset ? (no, yes)
-50... 50 °C
--
8703
I
Outside temp attenuated
Reset ? (no, yes)
-50... 50 °C
--
This is the average of the outside temperature over a 24-hour period.
This value is used for automatic Summer / Winter switchover (line 730).
8704
I
Outside temp composite
-50... 50 °C
--
The mixed outside temperature is a combination of the current outside temperature and the average outside temperature
calculated by the regulator. This value is used for calculating the initial temperature.
8730
I
Heating circuit pump, circuit 1
Off, On
Off
8731
I
Mixer valve HC1 open
Off, On
Off
8732
I
Mixer valve HC1 closed
Off, On
Off
8740
U
Room temperature 1
0 50 °C
--
Room setting 1
20 °C
8743
U
Flow temperature 1
0 140 °C
--
Flow temperature setpoint 1
--
8756
U
Cooling flow temperature 1
0 140 °C
--
Cooling flow temperature setpoint 1
--
8760
I
Heating circuit pump, circuit 2
Off, On
Off
8770
I
Room temperature 2
0 50 °C
--
Room setpoint 2
20 °C
8773
U
Flow temperature 2
0 140 °C
--
Flow temperature setpoint 2
--
8820
I
DHW pump
Off, On
Off
8821
I
El imm heater DHW
Off, On
Off
8830
U
DHW (domestic hot water) temperature
0 140 °C
--
DHW temperature setpoint
50 °C
8840
S
Hours run DHW pump
0... 2730 h
--
8841
S
Start counter DHW pump
0 199999
--
8842
S
Hours run electric DHW
0... 2730 h
--
8843
S
Start counter electric DHW
0 65535
--
8900
U
Swimming pool temperature
0 140 °C
--
Swimming pool temperature setpoint
22 °C
8950
I
Common flow temperature
0 140 °C
--
Common flow temperature setpoint
--
8957
I
Common flow setpoint, refrigeration
0 140 °C
--
8980
I
Not used
8981
I
Not used
Installation and operating manual "1585 - EN"
Air to Water Heat Pump (Split integrated DHW type)
- 54 -
Содержание WO A060LDC Series
Страница 19: ... Installation and operating manual 1585 EN 19 Air to Water Heat Pump Split integrated DHW type ...
Страница 70: ... Installation and operating manual 1585 EN Air to Water Heat Pump Split integrated DHW type 70 ...
Страница 71: ... Installation and operating manual 1585 EN 71 Air to Water Heat Pump Split integrated DHW type ...