2 .3 Installation position
The choice of the position for installation is particularly
important insofar as any later movement is a delicate
operation requiring the intervention of a qualified person.
Choose the site of the outdoor unit and the hydraulic
unit after discussion with the customer.
Observe the maximum and minimum distances between
the hydraulic unit and the outdoor unit (
figure 18, page 18
),
the guarantee of the performances and the system's
service life depend on this.
2 .4 Installation of the outdoor unit
2 .4 .1 Installation precautions
"
The outdoor unit must only be installed outdoor
(outdoors). If a shelter is required, it must have
broad openings on the 4 walls and observe the
installation clearances (
figure 11
).
• Choose a site that is preferably sunny and sheltered
from strong cold predominant winds (mistral,
tramontana, etc…).
• The unit must be easily accessible for future installation
and maintenance work (
figure 11
).
• Ensure that it is possible to make the connections to
the hydraulic unit easily.
• The outdoor unit is able to withstand bad weather but
avoid installing in a position where it is likely to be
exposed to significant dirt or flowing water (under a
defective gutter for example).
• Water may drain away from the outdoor unit when it
is operating. Do not install the appliance on a paved
terrace; choose a well-drained place (e.g. gravel
or sand). If the installation is in an area where the
temperature can be lower than 0°C for a long period,
check that the presence of ice does not present any
danger. A drainage pipe can also be connected to the
outdoor unit (
figure 12, page 14
).
• Nothing should obstruct the air circulation through the
evaporator and from the fan (
figure 11
).
• Keep the outdoor unit away from heat sources and
inflammable products.
• Make sure the appliance not disturb the surrounding
area or users (noise level, draught generated, low
temperature of the air being blown out, with the risk of
freezing plants in its path).
figure 11 - Minimum installation clearances around outside unit (all models)
600 mm
or more
100 mm
or more
250 mm or more
(Service space)
100 mm
or more
300 mm
or more
600 mm or more
250 mm
or more
250 mm
or more
300 mm
or more
600 mm or mor
e
100 mm
or more
100 mm
or mor
e
300 mm or mor
e
(Ser
vic
e spac
e)
300 mm
or more
Installation and operating manual "1585 - EN"
- 13 -
Air to Water Heat Pump (Split integrated DHW type)
"
Model Comfort 5, 6 & 8
"
Model Comfort 10
Содержание WO A060LDC Series
Страница 19: ... Installation and operating manual 1585 EN 19 Air to Water Heat Pump Split integrated DHW type ...
Страница 70: ... Installation and operating manual 1585 EN Air to Water Heat Pump Split integrated DHW type 70 ...
Страница 71: ... Installation and operating manual 1585 EN 71 Air to Water Heat Pump Split integrated DHW type ...