2 .7 .3 Additional charge
The charge in the outside units corresponds to the maximum distances between the outside unit and the hydraulic
module defined in
page 18
. For some distances, an additional charge of R410A is required. The additional
charge depends on the distance between the outside unit and the hydraulic module for each type of appliance.
The additional charge of R410A must necessarily be made by an approved refrigeration engineer.
e 5, 6
(Outdoor unit WOYA060LDC)
7.5m < Length of the connections ≤ 15m
15m < Length of the connections ≤ 20m
[0.03 x (Length of the connections - 7.5) + 0.175] x 1000 = g
[0.02 x (Length of the connections - 15) + 0.4] x 1000 = g
If the temperature control set on the hydraulic module is less than or equal to 0.4, an additional charge must be
added from 5m refrigerant piping according to the formula: 0.03 x (length of the connections - 5) + 0.1.
Length of the
connections m
8
9
10
11
12
13
14
15
16
17
18
19
20
Charge g
1290
1320
1350
1380
1410
1440
1470
1500
1520
1540
1560
1580
1600
e 8
(Outdoor unit WOYA080LDC)
7.5m < Length of the connections ≤ 20m
[0.02 x (Length of the connections - 7.5)] x 1000 = g
Length of the
connections m
11
12
13
14
15
16
17
18
19
20
Charge g
1470
1490
1510
1530
1550
1570
1590
1610
1630
1650
e 10
(Outdoor unit WOYA100LDT)
7.5m < Length of the connections ≤ 15m
15m < Length of the connections ≤ 20m
[0.04 x (Length of the connections - 7.5)] x 1000 = g
[0.05 x (Length of the connections - 15) + 0.3] x 1000 = g
Length of the
connections m
10
11
12
13
14
15
16
17
18
19
20
Charge g
1900
1940
1980
2020
2060
2100
2150
2200
2250
2300
2350
Installation and operating manual "1585 - EN"
Air to Water Heat Pump (Split integrated DHW type)
- 22 -
Comfort 5, 6
Comfort 8
Comfort 10