3
WARNING
Lubricants
Do NOT use Vaseline, oils, hydrocarbon lubricants or spray silicone anywhere! Petroleum base lubricants
will cause swelling of o-rings and seals. The use of other lubricants may attack plastic Noryl®. It is recom
-
mended that Dow Corning® silicone grease be used as a lubricant for all control valves. Dow Corning® 7
Release Compound is used in the manufacture of Chandler Systems control valves. (Part # LT-150)
Sealants
Pipe dope and liquid thread sealers may contain a carrier that attacks some plastic materials. It is recom
-
mended that Teflon® tape be used to seal plastic Noryl® threaded fittings.
Res-Up
The use of Res-Up or any other resin cleaners is prohibited. These cause deterioration of the control valve
and VOIDS warranty.
Softener Specifications
General Specifications
CD24
CD32
Grains Capacity / Lbs Salt Used* per regeneration
20,000 / 7.5
27,000 / 9
Maximum Raw Water Hardness (grains)
50
75
Maximum Clear Iron / Manganese (ppm)
3
5
Exchange Resin (cu ft )
.75
1.0
Mineral Tank (polyglass)
9 x 35
9 x 35
Service Flow Rate** (gpm)
10.0
11.0
Backwash Flow Rate (gpm)
2.0
2.0
Gallons Used / Regeneration
86
88
Space Required
23x14x 45
23x14x45
Approximate Shipping Weight (lbs)
88
100