Troubleshooting Guide

SYMPTOM

PROBABLE CAUSE

CORRECTION

1.Softener Fails to 

   Regenerate 

   Automatically

Power supply plugged into 

intermittent or dead power source

Connect to constant power source

Disconnected meter cable

Reconnect cable

Improper control valve 

programming

Reset program settings

Defective power supply

Replace power supply

Meter is dirty or defective

Clean or replace meter assembly

Defective Drive motor

Replace motor

2. Regeneration at 

    Wrong Time

Time of day improperly set, due to 

power failure

Reset time of day programming and 

install 9-volt battery.

Regeneration time set improperly

Reset regeneration time program-

ming

3. Loss of Capacity

Increased raw water hardness

Increase hardness setting or de-

crease days between regeneration

Brine concentration and or / quan-

tity

Keep brine tank full of salt at all 

times. Clean it yearly. Salt may be 

bridged. If using a salt grid plate, 

ensure refill water is over it. 

Resin fouling

Call dealer. Find out how to con

-

firm it. Clean the resin and prevent 

future fouling. 

Poor distribution, channeling (un

-

even bed surface)

Call dealer. Check backwash flow. 

Regenerate more frequently

Internal valve leak

Call dealer. Replace spacers, seals 

and / or piston

Resin age

Call dealer. Check for resin oxidation 

caused by chlorine.  Mushy resin.

Resin loss

Call dealer. Check for correct bed 

depth. Broken distributor tube. Air 

or gas in bed: well gas eliminator. 

Loose brine line. 

4. Poor Water 

    Quality

Check items listed in #1, #2, and #3

Bypass valve open

Close bypass valve.

Channeling

Check for too slow or high service 

flow. Check for media fouling.

5. High Salt Usage

High salt setting

Lower brine tank refill time

Excessive water in brine tank

See symptom #7

Constant flow through the unit

Indicates plumbing leak (e.g. toilet 

tank)

Regenerating too frequently

Lower hardness setting or increase 

days between regeneration.

Service Instructions / Instructional Videos Available at www.watersoftinc.com

Содержание CD24

Страница 1: ...Cabinet Softener Manual Installation Operation Manual...

Страница 2: ...sembly Page 19 Bypass Assembly Page 20 Additional Information Page 21 Troubleshooting Page 23 Error Codes Page 25 Warranty Page 27 FCC Compliance Statement http www chandlersystemsinc com files FCC_Co...

Страница 3: ...that attacks some plastic materials It is recom mended that Teflon tape be used to seal plastic Noryl threaded fittings Res Up The use of Res Up or any other resin cleaners is prohibited These cause d...

Страница 4: ...ft water The surfaces of these beads are covered with sodium ions As hard water enters the mineral tank and comes into contact with the resin an exchange of ions takes place as dissolved Calcium and M...

Страница 5: ...to back up of hot water DO NOT install the unit in an area of direct sunlight or where freezing temperatures may occur See Installation Diagrams for proper placement and plumbing connections Major Sys...

Страница 6: ...6 Removal of Top Cabinet Lid PUSH CLIPS Installation...

Страница 7: ...this occur Caution If sweat soldering copper pipe remember to always use lead free solder and flux cover bypass valve with wet rags to prevent heat damage to connections and control valve If using PV...

Страница 8: ...line is advisable to keep the drain line full and assure correct flow during backwash Elbows or other fittings must be kept at a bare minimum Note Where the drain line is elevated above the control va...

Страница 9: ...ill flash 2 To set the Time of Day press the Set Change button First digit will flash Example 12 00 To change digit value press the Set Change button To accept the digit value press the Menu Enter but...

Страница 10: ...ine tank to fill just over the salt grid plate 3 Advance control valve to BRINE RINSE cycle 2 and allow the control valve to draw water from the brine tank until it stops If no draw is observed check...

Страница 11: ...will bypass the softener and be untreated You should manually bypass the softener if 1 The outside lines do not bypass the water softener and water is to be used for lawn sprinkling or other similar u...

Страница 12: ...To Fast Cycle thru regeneration First complete above 2 steps Note Press and hold the Set Change button for 3 seconds to advance to the next cycle step Fast Cycle is not necessary unless desired to man...

Страница 13: ...el this feature Example Override every 7 days A 07 default setting or cancel setting A 00 Maximum is 29 3 Regeneration Cycle Step Times Steps 1 2 3 4 Example 3 10 The next 4 displays set the duration...

Страница 14: ...the default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve d...

Страница 15: ...s in ORANGE with a set button can be changed For Filters Set Backwash Frequency This sets the amount of day between backwash cycles Change Time of Day Press SET to set time automatically based on devi...

Страница 16: ...p Option 2 Touch any graph to enlarge and see details Enlarged graphs are able to be zoomed in by pinching with two fingers Enlarged graph shown below Regenerate Unit at Next Regen Time button This wi...

Страница 17: ...27 11 20016X108 9 Power Flow Meter Motor 10 11 Ref Description Part Number Qty 1 Front Plate 20016X001 1 2 Encoder Wheel 20001X007 1 3 Cabinet Legacy Board Assembly 20016X101 1 4 Main Gear 21001X120 1...

Страница 18: ...17X100 1 7 Drain Elbow 20017X266 1 8 DLFC Clip 20017X214 1 9 Brine Valve 20251X225 1 10 BLFC Assy 20001X228 1 11 Brine Line Ferrule 20251X305 1 REF DESCRIPTION PART NO QTY 12 Injector Cap Screw 20001X...

Страница 19: ...20016X007 1 2 Resin Tank 30935X000 1 3 Brine Well Assembly 20016X008 1 4 Cabinet Cap 20016X009 1 5 Cabinet Lid 20016X010 1 6 Top Insert 20018X008 1 7 Front Insert 20018X009 1 8 Clear 3 8 Tubing 5ft 5...

Страница 20: ...20 Bypass Assembly REF DESCRIPTION PART NO QTY 1 D15 Bypass 20017X283 1 2 1 NPT 90 Elbow Set 20017X284 1 1 2 1 20017X283 D15 Bypass 2 20017X284 1 NPT 90 Elbow Set...

Страница 21: ...will now lift off easily 4 Put new powerhead on top of the valve Be sure the drive pin on main gear engages slot in drive yoke wide side of drive yoke upright must face to the left away from the motor...

Страница 22: ...er at piston drive yoke Remove powerhead mounting screws The entire powerhead assembly will now lift off easily Remove piston retaining plate screws 4 Pull upward on end of piston rod yoke until assem...

Страница 23: ...all times Clean it yearly Salt may be bridged If using a salt grid plate ensure refill water is over it Resin fouling Call dealer Find out how to con firm it Clean the resin and prevent future foulin...

Страница 24: ...items listed in 1 Improper control valve programming Check and reset programming Plugged restrict drain line Clean drain line and or flow control button Injector and or screen is plugged Clean or repl...

Страница 25: ...coder connection If the encoder is plugged in and snapped into place skip to step 2 below If encoder is disconnected reconnect it and cycle power to clear the error 2 Disconnect powerhead from valve b...

Страница 26: ...to one of the following factors The electrical outlet is not powered or is switched off The power cable has come unplugged from the circuit board The power supply has come unplugged from your electric...

Страница 27: ...ervice charges delivery expenses property damage administrative fees or any costs incurred by the purchaser in removing or reinstalling the water treatment equipment The Warranty does not cover any cl...

Страница 28: ...28 710 Orange Street Ashland OH 44805 PH 419 289 1500 FAX 419 289 1515 www watersoftinc com 0622TV...

Отзывы: