TROUBLESHOOTING
ENG2036-16/01/19
7.11 COLD
WATER
TROUBLESHOOTING
If the cold water temperature is above 12°C or at the same temperature as the ambient
water, follow the instructions below.
Symptoms
Causes
Solutions
Compressor is running, and
condenser [18] is warm, but
water is not cold.
Too much dispensing in
a small time depleted the
water cooling capacity;
Insufficient ventilation in
the condenser coil due to
lack of ventilation or dirty
condenser coil.
Wait for the tank to recover
before dispensing more
cold water, assure that the
condenser coil chapter
2.5 [18] is clean and with
enough space for correct
ventilation (minimum of 100
mm).
Check If the red and green
Switches are ON chapter 2.5
Compressor
is not running.
No power to refrigeration
elements.
[22] & [23].
Check power socket chapter
2.5 [25] and cable.
Check fuse chapter 2.5 [24].
Repair or replace compressor.
Check for leaks in the
refrigerant line, check the
condenser grill chapter 2.5
Compressor runs but
condenser[18] is not warm.
Refrigerant lost
Refrigerant line is blocked
[18] for damage first.
Shake the filter dryer to
see if you hear the shaking
noise of the elements inside.
If it does not shake, the
dryer is blocked.