12
ENG2036-15/01/19
Element Description
SV1
Cold water out
SV4
Ambient water
output
SV5
Hot water
output
SV6
Ice Bath fill
SV7
Inlet solenoid
E1
Hot tank
heating
E2
Compressor
E4
UV Firewall™
S1
Hot water
sensor
S2
Overheat
thermostat
S3
S4
S5
Ice Bath
probes
Function
Action
SV7+SV4+E4
SV7+SV1+E4
SV7+SV5
Click: E1 | Until S1>Extra Hot Setpoint
Dispense: SV7+SV5
SV7+SV6 | Until level
probe detects water
ON: S3/S4/S5 - No Ice On Probes
OFF: S3/S4/S5 - Ice On Probes
S1<SetPoint; E1=ON
S1≥SetPoint; E1=OFF
S2≥105°C; E1=OFF
Requires Manual Reset
PRODUCT INFORMATION
These diagrams are for reference only; some features might not be included on your
machine. More detailed information can be seen in Chapter 6.1 and electrical diagram
on Chapter 6.3.
Water configuration: cold, ambient and hot.
DRAIN VALVE
COLD WATER OUT
SV7
SV6
IN (Water)
OUT
(Water)
HOT WATER OUT
HOT
TANK
CONDENSER
FILTER
DRYER
SV5
SV4
SV1
VENT PIPE
E1
E4
S2
S1
S3/S4/S5