3
• The isolation for the water and electricity should be easily accessible, and the machine
should not be installed using an extension lead.
• The water outlet connection must be fitted with an install kit containing a non-return valve,
a pressure reducer (maximum 3 bar) and a water block device. Prepare the connection to
the machine from the install kit via a length of 1/4” John Guest food grade tubing.
• Remove the filter from the machine and flush it externally, making sure 10 litres of water
pass through the filter to clear any carbon fines that may need to be removed.
• Before turning ON the machine, take a glass of water from a faucet and check the
TDS levels. If the TDS is less than to 30ppm you need to add 2.5 grams of sodium
bicarbonate to the Ice Bath to ensure it works efficiently.
To start-up the product follow the instructions below. Some pre-installation piping is required
before installing the machine:
Unpack and carry out a visual inspection
of the unit. Open the front door (unscrewing
[9]) and visually inspect the internals
of the product.
1
2
Connect the water supply (chapter 2.5 [26]).
Ensure the
green
switch on the rear of the
machine (chapter 2.5 [22]) is in the OFF
position and connect the unit to a power
supply and CO
2
(check CO
2
instructions on
3.3 page 14).
Turn ON the
red
power switch (chapter 2.5 [23]) and follow instructions on the display screen.
It should take approximately 2 minutes to fill the Ice Bath and 30 more seconds to fill the s parkling
tank (model dependent
The Ice Bath water is not used for consumption, so the addition of the sodium b icarbonate as no
effect on the quality of the drinking water. To connect the water cooler to the mains water supply,
you will need to use a new set of connectors. Do not use connectors that where already used on
other installations. A pressure higher than 3.5 bar will damage the machine, a pressure reducing
valve is necessary.
4
Fill hot tank before turning ON the
green
switch:
1. Press the dispense button [12] until water
dispenses.
2.Turn ON
green
switch chapter 2.5 [22].
Check sanitizing instruction (chapter.3.2) to
complete the installation.
5
16
INSTALLATIO N INFORM ATION
ENG2036- 16/0 1/19