![WaterLogic WL7 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/waterlogic/wl7/wl7_technical-manual_3671415011.webp)
11
ENG2036-16/01/19
Element Description
SV1
Cold water out
SV2
Sparkling out
SV3
Sparkling in
SV4
Ambient water
output
SV5
Hot water
output
SV6
Ice Bath fill
SV7
Inlet solenoid
E1
Hot tank
heating
E2
Compressor
E3
Pump
E4
UV Firewall™
S1
Hot water
sensor
S2
Overheat
thermostat
S3
S4
S5
Ice Bath
probes
S6
Sparkling
level sensor
Function
Action
SV7+SV4+E4
SV7+SV1+E4
Dispense
SV2+E4
Fill
SV7+SV3+E3 Until S6 is satisfied
SV7+SV5
Click: E1 | Until S1>Extra Hot Setpoint
Dispense: SV7+SV5
SV7+SV6 | Until level
probe detects water
ON: S3/S4/S5 - No Ice On Probes
OFF: S3/S4/S5 - Ice On Probes
S1<SetPoint; E1=ON
S1≥SetPoint; E1=OFF
S2≥105°C; E1=OFF
Requires Manual Reset
PRODUCT INFORMATION
These diagrams are for reference and understanding the WL7 FW, some features might
not be included on your machine.
More detailed information can be seen in Chapter 6.1 and electrical diagram on Chapter 6.3.
Water configuration: cold, sparkling, ambient and hot.
DRAIN VALVE
COLD WATER OUT
SPARKLING WATER OUT
SV7
SV6
IN (Water)
OUT
(Water)
CO
2
In
PUMP
CHECK
VALVE
HOT WATER OUT
HOT
TANK
CONDENSER
FILTER
DRYER
CHECK VALVE
SV5
SV4
SV1
SV2
AMBIENT WATER OUT
VENT PIPE
SV3
E1
E3
E4
S2
S1
S3/S4/S5
S6
2.4 WATER FLOW DIAGRAM
Содержание WL7
Страница 1: ...WL7 FIREWALL Technical Manual ...
Страница 33: ...33 ENG2036 16 01 19 6 SCHEMATICS ...