WL400
Manual Page 63
–
Revision: 10-23-2019
FAULT CODE TROUBLESHOOTING INDEX
1.
Icon and Alarm on continuously
–
Leak Detector Sensor Alarm
2.
Icon ON Continuously, Alarm for 20 Seconds
–
the Firewall UV system is not
detecting adequate dose of UV to ensure safe water
1.
FAULT CODE:
Icon and Alarm on continuously
–
Leak Detector Sensor Alarm
There are two leak detector sensors in the
WL400
Water Treatment Systems.
Possible Reason
Solution
Leak Tray Full
Check for water in base cabinet by opening and removing
front cover.
If water is found in leak tray, dry out leak tray.
Unplug unit to reset fault and determine where the leak is.
Leak Tray Full
–
with no alarms
Verify the drip tray leak clips are installed.
If the drip tray leak clips are installed, the water TDS may be too low. You may need to bend
the drip tray sensor tabs inward (closer together) to improve the performance of the signal
returning to the board.
`Water in Base Cabinet
If no water is found in the base cabinet, open Top Cover of
WL400
Water Treatment System
and remove Right Side
Panel to determine where leak is.
If water is found, dry out leak tray, unplug unit to reset fault
and determine where the leak is.
Содержание WL400 Series
Страница 34: ...WL400 Manual Page 34 Revision 10 23 2019 WL400 BASE MAIN PARTS DRAWING AND PARTS LIST...
Страница 42: ...WL400 Manual Page 42 Revision 10 23 2019 BASE CABINET SIDE REMOVAL...
Страница 43: ...WL400 Manual Page 43 Revision 10 23 2019 BASE CABINET CONFIGURATION...
Страница 45: ...WL400 Manual Page 45 Revision 10 23 2019 INSIDE LEFT SIDE CABINET CONFIGURATION...
Страница 46: ...WL400 Manual Page 46 Revision 10 23 2019 INSIDE RIGHT SIDE CABINET CONFIGURATION...
Страница 48: ...WL400 Manual Page 48 Revision 10 23 2019 OLD RO Membrane 10 8060 Installed NEW RO Membrane 10 8061 Installed...