WL400
Manual Page 50
–
Revision: 10-23-2019
2.
Put 1 teaspoon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml = ½
cap full) of household bleach (Sodium Hypochlorite 5 - 10% Concentration) in the Sanitizing
Cartridge. Always ensure sanitizer is compatible with stainless steel and acetyl plastic.
3.
Connect sanitizing cartridge to inlet water supply and connect to inlet bulkhead fitting on back of
unit. Turn on water supply.
4.
Connect power to
WL400 Water Treatment System
. Turn on Red Power Switch. DO NOT TURN
ON GREEN HEATER/COMPRESSOR SWITCH AT THIS TIME.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK
.
Green Heater/Compressor Switch must be in the O=OFF position
while the hot tank is empty. Damage could occur within one
minute and the overloads (high limit) will require manual reset if
heater is turned on with an empty hot tank.
Fill the Cold Circuit with Sanitizer
5.
Depress the Main Dispensing Button on the Front Control Panel until cold water/sanitizing
solution comes out the faucet.
NOTE:
Container and drain basin will be required to catch the
water from the faucet.
WARNING!
Use Personal Protective Equipment. Gloves and Eye Protection Required. The first
2 or 3 gallons of water will contain concentrated sanitizer. Use extreme care!
6.
Turn off water supply and remove Sanitizing Cartridge from inlet water supply. Reconnect water
supply to Inlet Bulkhead Fitting.
Flushing the Sanitizer from the Machine
7.
Flush thoroughly
per filter manufacturers’ recommendation
with fresh water to drain.
8.
Once flushed, install the Filters. Following the flow direction on the filter.
NOTE:
Filters should not be flushed prior to 24 hours before installation to limit Microbial
Growth.
9.
Connect
WL400
Water Treatment System
to power.
Содержание WL400 Series
Страница 34: ...WL400 Manual Page 34 Revision 10 23 2019 WL400 BASE MAIN PARTS DRAWING AND PARTS LIST...
Страница 42: ...WL400 Manual Page 42 Revision 10 23 2019 BASE CABINET SIDE REMOVAL...
Страница 43: ...WL400 Manual Page 43 Revision 10 23 2019 BASE CABINET CONFIGURATION...
Страница 45: ...WL400 Manual Page 45 Revision 10 23 2019 INSIDE LEFT SIDE CABINET CONFIGURATION...
Страница 46: ...WL400 Manual Page 46 Revision 10 23 2019 INSIDE RIGHT SIDE CABINET CONFIGURATION...
Страница 48: ...WL400 Manual Page 48 Revision 10 23 2019 OLD RO Membrane 10 8060 Installed NEW RO Membrane 10 8061 Installed...