WARNING!
HOT CIRCUIT IS NOT SANITIZED.
Water in the hot circuit is not sanitary until the temperature exceeds 171
°
F (77
°
C) for at least 5
minutes.
UV System Functional Test
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet rays.
Never look directly at an operating UV light. Disconnect wiring before removing.
28.
Remove UV
Firewall™
Lamp from
Firewall™
housing. Remove Top Cover from
Firewall™
housing.
Carefully remove Quartz Sleeve Spiral from
Firewall™
Housing and inspect for cracks or other
damage. Reinsert Quartz Sleeve Spiral, replace top cover of housing. Inspect UV lamp and
reinsert into Housing.
29.
Press Dispensing Button and check for blue glow from top of
Firewall™
Housing and at Faucet
dispensing area to ensure UV lamp is operational.
30.
Disconnect UV lamp to test UV lamp sensor operation. Unit
should alarm and UV Icon on display will light.
31.
Disconnect power to
WL400
Water Treatment System.
32.
Reconnect UV lamp.
33.
Connect power to
WL400
Water Treatment System.
Compressor Test
34.
Switch Green Heater/Compressor to on
I=ON
position. Always ensure tanks are
full of water before turning on the heater or the overloads (high limit) will open
and require manual reset. If the wire condenser at back of the unit is warm, the
refrigeration system is working.
35.
Once the
WL400 Water Treatment System
reaches its target temperature, the compressor will
shut off. Draw a glass of cold water and verify it is has been chilled to proper temperature.
Heater Test
Содержание WL400 Series
Страница 34: ...WL400 Manual Page 34 Revision 10 23 2019 WL400 BASE MAIN PARTS DRAWING AND PARTS LIST...
Страница 42: ...WL400 Manual Page 42 Revision 10 23 2019 BASE CABINET SIDE REMOVAL...
Страница 43: ...WL400 Manual Page 43 Revision 10 23 2019 BASE CABINET CONFIGURATION...
Страница 45: ...WL400 Manual Page 45 Revision 10 23 2019 INSIDE LEFT SIDE CABINET CONFIGURATION...
Страница 46: ...WL400 Manual Page 46 Revision 10 23 2019 INSIDE RIGHT SIDE CABINET CONFIGURATION...
Страница 48: ...WL400 Manual Page 48 Revision 10 23 2019 OLD RO Membrane 10 8060 Installed NEW RO Membrane 10 8061 Installed...