WL2 FW
Manual
Page 78 – Revision EU05-07-17
PROGRAMMING INSTRUCTIONS
CHANGING HOT WATER MODE TO AMBIENT WATER
WL2FW Water Treatment Systems
comes with set to Hot / Cold, which can be changed to
Ambient / Cold settings. On the
Energy Saver PCB,
Move the Jumper on JP9 from Pins 1 and 2 to
Pins 2 and 3.
Unplug Power Cord and remove Top Cover to access Energy Saver PCB.
WL2FW Water Treatment Systems
comes with Hot and
Cold Water factory settings.
PCB Jumper JP9 in positions - Pin 1 and 2
1 2
Change to Ambient and Cold by moving PCB Jumper
JP9 to positions – Pin 2 and 3
2 3
Pin Numbers
1
2
3
Energy Saver PCB – P/N EN-6131 – WLCP PN 20-0075