WL2 FW
Manual
Page 21 – Revision EU05-07-17
REPLACEMENT COMPONENTS - CONSUMABLES
➢
Waterlogic
technical manuals cover voltages of both 120v and 220v for all our markets.
Please ensure that you carefully read the information in this manual and for any parts specific
to any market, refer to your technical agreement or specific part listing.
Component
Part Number
Frequency of Replacement
UV Light Assembly, 15 Watts
CT-2085-A
Every 6 months, or as required.
UV Spiral Quartz
FU-0007
Clean every 6 months, or as required and
replace as needed.
Hot Tank 87°C (187°F)
220v/50Hz
Hot Tank 87°C (187°F)
120v/60Hz
HT-3042
HT-3041
Replace every 3 to 5 years depending on usage.
1-Micron CBC Cyst / Lead
Reduction Filter Assembly NSF
53 *
FT-0063
Local water conditions will determine proper
filter type and maintenance schedule.
Replacement parts can be obtained from
Waterlogic
or an
Authorized Waterlogic Dealer
.
See Parts Layouts, Drawings, and Parts Lists for additional repair parts.
Hot Tank Service
Hot Tanks (with controls) must be replaced at least every 3 to 5 years depending on usage.
Descaling Hot Tank may be required on a regular basis depending upon filtration and local water
conditions. See Service Section.
NOTE
:
At the
end of this product’s life
, ensure that it is disposed of in an environmentally friendly manner
which is fully compliant
with all Local Requirements and Guidelines.
Содержание WL2FW FIREWALL Series
Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...