Page 59 – Revision EU05-07-17
3.
Dispensing Won’t Stop When Not Holding the Dispensing Button
Possible Reason
Solution
Too much water pressure.
Recommend 2.7 to 4 bar for
the
WL2FW Water Treatment
System
to operate properly.
The correct input water pressure is critical to the performance of
the unit to allow solenoids to open.
Check water pressure at the inlet bulkhead with a water pressure
gauge.
Additional method of verification is to turn off water to unit and
press the dispense button. Does the solenoid open without
water pressure to the unit? Listen for solenoid to activate, not
button “click”.
Adjust water pressure to 2.7-4bar.
Bad Display PCB
Replace Main PCB
Part Number: EN-6126-A
Debris in the Solenoid
Inspect Solenoid for debris and clean out as needed.
Dispensing Button Stuck
Dirt or Foreign material is filling the gap around the push-buttons.
Inspect the push buttons and clean surrounding area. Inspect
faucet assembly inside the unit and clean as necessary.
4.
Steady Drip Out of Faucet
Possible Reason
Solution
Debris in Solenoid
Inspect Solenoid for debris and clean out as needed.
5.
Hot Water or Steam Coming out of both the Faucet and Vent Hole
Possible Reason
Solution
Improper tubing attachment
from the Hot Tank to Faucet or
vice versa.
Check that the tubing is connected from Hot Tank Outlets to
correct Faucet attachments. Connect tubing to outlets as
needed.
Содержание WL2FW FIREWALL Series
Страница 14: ...WL2 FW Manual Page 14 Revision EU05 07 17 HEATER CIRCUIT HOT TANK WIRING...
Страница 37: ...WL2 FW Manual Page 36 Revision EU05 07 17 WL2FW FLOW DIAGRAM COLD ONLY...
Страница 38: ...WL2 FW Manual Page 37 Revision EU05 07 17 COLD AND AMBIENT...
Страница 39: ...WL2 FW Manual Page 38 Revision EU05 07 17 HOT AND COLD...
Страница 41: ...WL2 FW Manual Page 40 Revision EU05 07 17...
Страница 42: ...WL2 FW Manual Page 41 Revision EU05 07 17 120V 60Hz Power Source 120V 60Hz 120V 60Hz...
Страница 43: ...Power Source 120V 60Hz 120V 60Hz 120V 60Hz WL2 FW Manual Page 42 Revision EU05 07 17...