WL200
Operating,
Installation,
and
Service
Manual
Page
34
‐
Revision:
4
‐
13
‐
2016
POWER
TROUBLESHOOTING
INDEX
1. Red Power Switch is lit but the red LED on the Front is not lit
2. Compressor Runs but does Not Chill
3. Compressor is Not Running
Red
Power
Switch
is
lit
but
the
Red
LED
on
the
Front
is
not
lit
Possible
Reason
Solution
Bad
Transformer
Replace
Transformer
Black
Power
Connector
to
the
PCB
is
not
properly
connected
Properly
connect.
Bad
Front
PCB
Replace
Front
PCB
Part
Number:
EN
‐
6086
/
Waterlogic
P/N
12
‐
8615.
Defective
Red
Power
/
Compressor
Switch
Replace
Power
Heater
/
Compressor
Switch
Compressor
Runs
But
Does
Not
Chill
Possible
Reason
Solution
Condenser
is
dirty
Clean
the
condensing
coil
of
any
obstructions
or
dust.
Reduction
of
airflow
into
unit.
Make
sure
unit
is
not
under
minimum
ventilation
requirements
(2
to
4
inches).
Compressor
is
running
very
hot.
Low
or
lost
refrigerant.
Refrigerant
recharge
required.