WL200

 

Operating,

 

Installation,

 

and

 

Service

 

Manual

                                                                      

Page

 

18

 ‐ 

Revision:

   

4

13

2016

 

INSTALLATION

 

PROCEDURES

 

 

Safety

 

and

 

Installation

 

Guidelines

 

Ensure

 

all

 

Local,

 

State,

 

and

 

Federal

 

Laws

 

and

 

Codes

 

including

 

health

 

and

 

safety

 

guidelines

 

are

 

met

 

when

 

installing

 

Waterlogic

 

Equipment.

   

Only

 

qualified

 

service

 

technicians

 

should

 

attempt

 

installation

 

and

 

service

 

of

 

Waterlogic

 

Equipment.

     

 

       

WARNING!

  

ELECTRICAL

 

SHOCK

 

HAZARD.

  

Always

 

unplug

 

(isolate

 

from

 

power

 

supply)

 

to

 

prevent

 

electrical

 

shock

 

except

 

where

 

electrical

 

tests

 

are

 

specified.

   

 

       

WARNING!

  

IMPROPER

 

SUPPLY

 

OR

 

CONNECTION

 

CAN

 

RESULT

 

IS

 

RISK

 

OF

 

SHOCK.

 

Connect

 

to

 

a

 

15

 

amp

 

120V

 

60Hz

 

properly

 

grounded

 

outlet

 

(GFI

 

is

 

recommended).

  

Ensure

 

polarity

 

is

 

correct

 

and

 

always

 

use

 

a

 

3

prong

 

outlet.

  

Consult

 

a

 

qualified

 

electrician

 

if

 

you

 

have

 

any

 

questions.

     

 

       

WARNING!

  

USE

 

ONLY

 

Waterlogic

 

SUPPLIED

 

POWER

 

CORD.

  

Locate

 

system

 

within

 

5

 

feet

 

of

 

power

 

supply.

  

Never

 

use

 

an

 

extension

 

cord

 

or

 

adapter.

  

Do

 

not

 

use

 

a

 

damaged

 

power

 

cord

 

or

 

plug.

  

Keep

 

power

 

cord

 

out

 

of

 

heavy

 

traffic

 

areas

 

and

 

away

 

from

 

heat

 

sources.

  

Do

 

not,

 

under

 

any

 

circumstances,

 

remove

 

ground

 

prong

 

or

 

alter

 

the

 

power

 

cord.

  

Never

 

pull

 

the

 

power

 

plug

 

from

 

the

 

outlet

 

with

 

a

 

wet

 

hand

 

or

 

allow

 

the

 

plug

 

to

 

get

 

wet.

  

Failure

 

to

 

use

 

the

 

supplied

 

power

 

cord

 

will

 

void

 

UL

 

Certification

 

and

 

Warranty.

   

 

      

CAUTION!

  

INDOOR

 

USE

 

ONLY

.

   

Never

 

expose

 

to

 

direct

 

sunlight,

 

heat

 

sources,

 

or

 

ambient

 

air

 

temperature

 

above

 

100°F

 

(37°C)

 

or

 

below

 

35°F

 

(2°C).

  

Install

 

indoors

 

and

 

keep

 

unit

 

away

 

from

 

excessive

 

humidity.

  

Never

 

expose

 

to

 

freezing

 

temperatures.

  

Ensure

 

there

 

is

 

adequate

 

clearance

 

around

 

the

 

unit

 

to

 

allow

 

refrigeration

 

system

 

condenser

 

to

 

dissipate

 

heat.

  

Warmer

 

environments

 

require

 

more

 

clearance

 

around

 

the

 

unit.

  

Minimum

 

clearance

 

around

 

all

 

surfaces

 

of

 

the

 

machine

 

is

 

2

inches.

  

Installs

 

where

 

the

 

ambient

 

temperature

 

exceed

 

80F,

 

require

 

a

 

minimum

 

of

 

4

inches

 

clearance

 

for

 

proper

 

heat

 

dissipation

 

and

 

efficient

 

operation.

    

 

       

CAUTION!

  

USE

 

A

 

WATER

 

PRESSURE

 

REGULATOR.

 

Waterlogic

 

will

 

not

 

be

 

responsible

 

for

 

injury

 

or

 

damage

 

caused

 

by

 

excessive

 

water

 

pressure.

  

Operating

 

pressure

 

must

 

be

 

40

 

psi

 

to

 

60

 

psi.

  

Be

 

aware

 

any

 

of

 

potential

 

pressure

 

surges

 

caused

 

by

 

building/municipal

 

pumping

 

stations.

   

 

       

CAUTION!

  

USE

 

UV

 

STABILIZED

 

SUPPLY

 

LINES.

  

Feed

 

the

 

unit

 

with

 

a

 

potable

 

ambient

 

or

 

cold

 

water

 

supply

 

only.

  

Feed

 

water

 

over

 

100°

 

F

 

(37°C)

 

can

 

damage

 

the

 

treatment

 

components.

  

Water

 

block

 

devices

 

and

 

external

 

leak

 

detectors

 

are

 

strongly

 

recommended.

 

Locate

 

the

 

unit

 

as

 

close

 

to

 

the

 

water

 

supply

 

and

 

the

 

electrical

 

connections

 

as

 

possible.

   

 

       

WARNING!

  

STORE

 

AND

 

TRANSPORT

 

UNIT

 

EMPTY.

 

  

ALWAYS

 

SANITIZE

 

BEFORE

 

USE.

 

The

 

unit

 

must

 

be

 

completely

 

drained

 

and

 

sealed

 

before

 

storing

 

to

 

avoid

 

stagnation

 

and

 

reduce

 

microbiological

 

contamination

 

(potential

 

bacterial

 

growth).

  

Sanitize

 

before

 

use

 

to

 

eliminate

 

any

 

potential

 

microbiological

 

contaminates

 

 

Pre

installation

 

and

 

sanitization

 

procedures

 

as

 

prescribed

 

in

 

this

 

manual

 

must

 

be

 

performed

 

before

 

installing

 

the

 

WL200

.

 

 

Always

 

install

 

indoors

 

and

 

place

 

the

 

Waterlogic

 

WL200

 

on

 

a

 

firm,

 

flat

 

and

 

stable

 

surface.

     

 
 

Содержание WL200

Страница 1: ...aterlogic Commercial Products LLC 11710 Stonegate Circle Omaha NE 68164 800 288 1891 www waterlogic us Tech Portal Website http techportal waterlogic com WL200 OPERATING INSTALLATION AND SERVICE MANUA...

Страница 2: ...The Waterlogic WL200 provides exceptional quality and great tasting water with every use TABLE OF CONTENTS Features and Benefits 3 Certifications 4 Introduction and Safety Alert Symbols 5 Safety Preca...

Страница 3: ...ty Counter Top has 2 liters of Cold Water Capacity BioCote Anti Microbial Protection Plastic surfaces surrounding dispensing areas and drip tray are infused with an exclusive silver additive called Bi...

Страница 4: ...or Drinking Water Coolers BPA Free Waterlogic tests for BPA and declares that all of its products are Bisphenol A FREE and contain no harmful BPA plastics Waterlogic manufacturing is certified to ISO...

Страница 5: ...ufactured and marketed by Waterlogic and its affiliates are protected by patents issued or pending in the United States and other countries Waterlogic reserves the right to change the specifications r...

Страница 6: ...water of unknown quality without adequate disinfection before or after the system The system is designed for the supplemental bactericidal treatment of either treated and disinfected public drinking w...

Страница 7: ...Maximum Service Pressure 100 psi 689 kPa Use Pressure Regulator Rated Service Flow 0 5 gallons per minute 1 89 Lpm Environmental Temperature 35 100 F 2 37 C Refrigerant Gas R134a 40g 1 41 ounces R134a...

Страница 8: ...llation and Service Manual Page 8 Revision 4 13 2016 OPERATING INSTRUCTIONS The above picture shows front LCD display and control panel for the Waterlogic WL200 For Cold Water Press the Dispensing But...

Страница 9: ...WL200 Operating Installation and Service Manual Page 9 Revision 4 13 2016 WL200 COUNTER TOP WATER FLOW DIAGRAM...

Страница 10: ...WL200 Operating Installation and Service Manual Page 10 Revision 4 13 2016 Water In Filter Dryer Solenoid Valve Compressor Condenser Water Out Faucet WL200 TOWER WATER FLOW DIAGRAM...

Страница 11: ...erature and the range is approximately 20 F thru the full range of adjustment 7 00 to the 5 00 positions You should be able to turn the screw from the factory set point of 41 F 12 00 position about 45...

Страница 12: ...nd check exterior for damage Sanitizing Sanitize using a Household Bleach 5 25 Sodium Hypochlorite solution or other approved cleaner throughout the cold and sparkling water circuits Follow all instru...

Страница 13: ...nd specified to do the job given the local water conditions usage maintenance schedule and placement restrictions In order for the filters to perform as represented and to provide the best quality wat...

Страница 14: ...faucet of the WL200 11 Flush the Cold Tank Run several gallons of water through the faucet by dispensing cold water to dilute and remove the sanitizer from the cold circuit You can use chlorine test s...

Страница 15: ...Red Power Switch to disable compressor O OFF Turn off Water Supply and Bleed Water Pressure 2 Isolate the unit from feed water by turning off the supply 3 Dispense cold still water to relieve any pre...

Страница 16: ...Installation and Service Manual Page 16 Revision 4 13 2016 8 Disconnect tubing from inlet elbow from solenoid and allow water to drain 9 Reconnect tubing into inlet elbow 10 Dry inside of unit 11 Repl...

Страница 17: ...ater Supply and Bleed Water Pressure 2 Isolate the unit from feed water by turning off the supply 3 Dispense cold still water to relieve any pressure built up in the system 4 Remove the water supply l...

Страница 18: ...w 35 F 2 C Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser t...

Страница 19: ...of water is obtained Once a continuous flow is obtained release the dispensing button Cold tank is now full 5 Move the Waterlogic WL200 into its final operating position Be sure that a minimum of 2 cl...

Страница 20: ...or damage DANGER HIGH VOLTAGE ELECTRICAL HAZARD Unplug before inspection and service 2 Ensure there is adequate minimum of 2 clearance around the unit and clean the condenser grill and compressor fan...

Страница 21: ...WL200 Operating Installation and Service Manual Page 21 Revision 4 13 2016 WL200 COUNTER TOP DRAWINGS with PART NUMBERS Wetted Parts...

Страница 22: ...CT 2016 Cold Tank Thermostat included with Cold Tank 12 1101 Yes 4 ST 8216 Silver Back Panel Counter Top Only 12 8061 Yes 5 EL 5016 Power Line Noise Filter ElectroMagnetic Interference filter EMI 10...

Страница 23: ...Feet Counter Top Only 12 3150 Yes 13 PU 4008 A 1 4 Union Elbow John Guest P N P10308S Purchase from John Guest No 14 PU 4016 Solenoid Valve 1000 mm 12 1500 Yes 14 1 CU 0001 Solenoid Cushion CU 0001 Ye...

Страница 24: ...8605 Yes 21 PL 1100 Silicon Button Key Mat Cold only 12 8600 Yes 22 PL 0084 L00 CL Front Upper Insert Panel Charcoal NA No 23 LP 7085 Button Label Cold only 12 8610 Yes 24 PL 1152 Drip Tray Grill Char...

Страница 25: ...Counter Top Only 12 3165 Yes 32 CT 2060 2L UV Cold Tank Assembly Counter Top Only 12 3110 Yes 33 EN 6111 A Leak Detection PCB NA No 33 1 EN 6059 PCB Stand off Pin 10 3017 Yes 34 PU 4007 A 5 16 x Reduc...

Страница 26: ...WL200 Operating Installation and Service Manual Page 26 Revision 4 13 2016 WL200 TOWER DRAWINGS with PART NUMBERS Wetted Parts...

Страница 27: ...15A with One Wire EL 5053 Yes 3 1 EL 5010 Fuse 120V 15A 10 3013 Yes 4 EL 5019 A Red Power and Compressor Switch 12 5600 Yes 5 CT 2016 Cold Tank Thermostat included with Cold Tank 12 1101 Yes 6 ST 813...

Страница 28: ...12 1500 Yes 13 1 CU 0001 Solenoid Cushion CU 0001 Yes 14 PU 4008 A 1 4 Union Elbow John Guest P N P10308S Purchase from John Guest No 15 PU 4007 A 5 16 x Reducing Elbow John Guest P N PI211008S Purcha...

Страница 29: ...146 Front Upper Drip Tray Insert Panel 12 8050 Yes 21 EN 6086 PCB for Cold Water 12 8615 Yes 22 PL 1180 CN PCB Cover 12 8605 Yes 23 PL 1100 Silicon Button Key Mat Cold only 12 8600 Yes 24 PL 0084 L00...

Страница 30: ...2017 4L Single Cold Tank Assembly Tower Only 12 1100 Yes 30 EL 5003 A Power Transformer 120V 12 3117 Yes 31 ST 8136 R2 Upper Shelf Tower Only 12 8003 Yes 32 CO 9027 Wire Condenser Tower Only 12 8102 S...

Страница 31: ...Service Manual Page 31 Revision 4 13 2016 WL200 COUNTER TOP ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technic...

Страница 32: ...and Service Manual Page 32 Revision 4 13 2016 WL200 TOWER ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technician...

Страница 33: ...run out of cold water Cold tank capacity is 4 liters for Tower and 2 liters for Counter Top Wait for cold tank to chill water to temperature prior to dispensing more cold water A greater capacity of W...

Страница 34: ...mer Black Power Connector to the PCB is not properly connected Properly connect Bad Front PCB Replace Front PCB Part Number EN 6086 Waterlogic P N 12 8615 Defective Red Power Compressor Switch Replace...

Страница 35: ...ition Turn Red Power and Compressor Switch on I ON Compressor Starting Circuit Turn Red Power and Compressor Switch off O OFF Remove the compressor cap on side of the compressor Disconnect the black a...

Страница 36: ...ng won t stop when not holding the Dispensing Button 3 Steady Drip out of Faucet 4 Water does not dispense from unit 5 Cold Water dispenses from Faucet and Vent Outlet Simultaneously 6 Small amount of...

Страница 37: ...PCGB or Solenoid Connector Check that they are connected properly and tightened Solenoid If both the Water Pressure and PCB have been ruled out then it is the Solenoid Replace Solenoid Dispensing butt...

Страница 38: ...ch on unit is in the off position Turn Red Power and Compressor switch on I ON 15 Amp Fuse Blown Replace the 15 Amp Fuse as needed Water is present in the bottom tray causing the leak detection to tri...

Страница 39: ...enses from Faucet Automatically Possible Reason Solution Cold or Hot Water solenoid valve malfunction Inspect valve components for proper function Replace as necessary Obstruction in solenoid housing...

Страница 40: ...leased to the faucet The inlet solenoid controls flow into the tanks The tanks will depressurize once the dispense button is released the inlet solenoid closes A small amount of water will Run On thro...

Страница 41: ...tion to Waterlogic for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporting...

Отзывы: