WL200
Operating,
Installation,
and
Service
Manual
Page
18
‐
Revision:
4
‐
13
‐
2016
INSTALLATION
PROCEDURES
Safety
and
Installation
Guidelines
Ensure
all
Local,
State,
and
Federal
Laws
and
Codes
including
health
and
safety
guidelines
are
met
when
installing
Waterlogic
Equipment.
Only
qualified
service
technicians
should
attempt
installation
and
service
of
Waterlogic
Equipment.
WARNING!
ELECTRICAL
SHOCK
HAZARD.
Always
unplug
(isolate
from
power
supply)
to
prevent
electrical
shock
except
where
electrical
tests
are
specified.
WARNING!
IMPROPER
SUPPLY
OR
CONNECTION
CAN
RESULT
IS
RISK
OF
SHOCK.
Connect
to
a
15
amp
120V
60Hz
properly
grounded
outlet
(GFI
is
recommended).
Ensure
polarity
is
correct
and
always
use
a
3
‐
prong
outlet.
Consult
a
qualified
electrician
if
you
have
any
questions.
WARNING!
USE
ONLY
Waterlogic
SUPPLIED
POWER
CORD.
Locate
system
within
5
feet
of
power
supply.
Never
use
an
extension
cord
or
adapter.
Do
not
use
a
damaged
power
cord
or
plug.
Keep
power
cord
out
of
heavy
traffic
areas
and
away
from
heat
sources.
Do
not,
under
any
circumstances,
remove
ground
prong
or
alter
the
power
cord.
Never
pull
the
power
plug
from
the
outlet
with
a
wet
hand
or
allow
the
plug
to
get
wet.
Failure
to
use
the
supplied
power
cord
will
void
UL
Certification
and
Warranty.
CAUTION!
INDOOR
USE
ONLY
.
Never
expose
to
direct
sunlight,
heat
sources,
or
ambient
air
temperature
above
100°F
(37°C)
or
below
35°F
(2°C).
Install
indoors
and
keep
unit
away
from
excessive
humidity.
Never
expose
to
freezing
temperatures.
Ensure
there
is
adequate
clearance
around
the
unit
to
allow
refrigeration
system
condenser
to
dissipate
heat.
Warmer
environments
require
more
clearance
around
the
unit.
Minimum
clearance
around
all
surfaces
of
the
machine
is
2
‐
inches.
Installs
where
the
ambient
temperature
exceed
80F,
require
a
minimum
of
4
‐
inches
clearance
for
proper
heat
dissipation
and
efficient
operation.
CAUTION!
USE
A
WATER
PRESSURE
REGULATOR.
Waterlogic
will
not
be
responsible
for
injury
or
damage
caused
by
excessive
water
pressure.
Operating
pressure
must
be
40
psi
to
60
psi.
Be
aware
any
of
potential
pressure
surges
caused
by
building/municipal
pumping
stations.
CAUTION!
USE
UV
STABILIZED
SUPPLY
LINES.
Feed
the
unit
with
a
potable
ambient
or
cold
water
supply
only.
Feed
water
over
100°
F
(37°C)
can
damage
the
treatment
components.
Water
block
devices
and
external
leak
detectors
are
strongly
recommended.
Locate
the
unit
as
close
to
the
water
supply
and
the
electrical
connections
as
possible.
WARNING!
STORE
AND
TRANSPORT
UNIT
EMPTY.
ALWAYS
SANITIZE
BEFORE
USE.
The
unit
must
be
completely
drained
and
sealed
before
storing
to
avoid
stagnation
and
reduce
microbiological
contamination
(potential
bacterial
growth).
Sanitize
before
use
to
eliminate
any
potential
microbiological
contaminates
Pre
‐
installation
and
sanitization
procedures
as
prescribed
in
this
manual
must
be
performed
before
installing
the
WL200
.
Always
install
indoors
and
place
the
Waterlogic
WL200
on
a
firm,
flat
and
stable
surface.