manualshive.com logo in svg
background image

 

WL200

 

Operating,

 

Installation,

 

and

 

Service

 

Manual

                                                                      

Page

 

20

 ‐ 

Revision:

   

4

13

2016

 

SERVICE

 

REQUIREMENTS

 

 

  

     

WARNING!

  

Read

 

and

 

understand

 

the

 

contents

 

of

 

this

 

manual

 

before

 

attempting

 

to

 

service

 

WL200.

 

Failure

 

to

 

follow

 

the

 

instructions

 

in

 

this

 

manual

 

could

 

result

 

in

 

death,

 

serious

 

personal

 

injury,

 

or

 

severe

 

property

 

damage.

  

Only

 

trained

 

and

 

qualified

 

technicians

 

should

 

attempt

 

to

 

install,

 

maintain,

 

or

 

service

 

Waterlogic

 

Equipment.

 

 

1.

 

Visually

 

inspect

 

all

 

electrical

 

and

 

water

 

connections

 

for

 

signs

 

of

 

wear

 

or

 

damage.

  

 

DANGER!

  

HIGH

 

VOLTAGE

 

ELECTRICAL

 

HAZARD.

  

Unplug

 

before

 

inspection

 

and

 

service.

 

 

2.

 

Ensure

 

there

 

is

 

adequate

 

(minimum

 

of

 

2”)

 

clearance

 

around

 

the

 

unit

 

and

 

clean

 

the

 

condenser

 

grill

 

and

 

compressor

 

fan

 

to

 

provide

 

efficient

 

cooling

 

system

 

operation.

 

 

3.

 

Sanitize

 

the

 

cold

 

tank

 

per

 

instructions

 

in

 

the

 

pre

installation

 

procedures.

 

 

4.

 

Clean

 

and

 

sanitize

 

external

 

surfaces

 

of

 

the

 

unit.

  

Use

 

soap

 

and

 

water

 

or

 

chemicals

 

that

 

are

 

compatible

 

with

 

ABS

 

plastic

 

and

 

will

 

not

 

damage

 

or

 

degrade

 

the

 

product

 

surfaces.

  

 

5.

 

 

Remove

 

and

 

clean

 

the

 

Faucet.

  

Replace

 

as

 

needed.

 

 

WARNING!

  

SANITIZER

 

MAY

 

CONTAIN

 

HAZARDOUS

 

CHEMICALS.

 

 

Use

 

of

 

proper

 

personal

 

protective

 

equipment

 

such

 

as

 

rubber

 

gloves

 

and

 

eye

 

protection

 

is

 

required.

   

 

 

 

Содержание WL200

Страница 1: ...aterlogic Commercial Products LLC 11710 Stonegate Circle Omaha NE 68164 800 288 1891 www waterlogic us Tech Portal Website http techportal waterlogic com WL200 OPERATING INSTALLATION AND SERVICE MANUA...

Страница 2: ...The Waterlogic WL200 provides exceptional quality and great tasting water with every use TABLE OF CONTENTS Features and Benefits 3 Certifications 4 Introduction and Safety Alert Symbols 5 Safety Preca...

Страница 3: ...ty Counter Top has 2 liters of Cold Water Capacity BioCote Anti Microbial Protection Plastic surfaces surrounding dispensing areas and drip tray are infused with an exclusive silver additive called Bi...

Страница 4: ...or Drinking Water Coolers BPA Free Waterlogic tests for BPA and declares that all of its products are Bisphenol A FREE and contain no harmful BPA plastics Waterlogic manufacturing is certified to ISO...

Страница 5: ...ufactured and marketed by Waterlogic and its affiliates are protected by patents issued or pending in the United States and other countries Waterlogic reserves the right to change the specifications r...

Страница 6: ...water of unknown quality without adequate disinfection before or after the system The system is designed for the supplemental bactericidal treatment of either treated and disinfected public drinking w...

Страница 7: ...Maximum Service Pressure 100 psi 689 kPa Use Pressure Regulator Rated Service Flow 0 5 gallons per minute 1 89 Lpm Environmental Temperature 35 100 F 2 37 C Refrigerant Gas R134a 40g 1 41 ounces R134a...

Страница 8: ...llation and Service Manual Page 8 Revision 4 13 2016 OPERATING INSTRUCTIONS The above picture shows front LCD display and control panel for the Waterlogic WL200 For Cold Water Press the Dispensing But...

Страница 9: ...WL200 Operating Installation and Service Manual Page 9 Revision 4 13 2016 WL200 COUNTER TOP WATER FLOW DIAGRAM...

Страница 10: ...WL200 Operating Installation and Service Manual Page 10 Revision 4 13 2016 Water In Filter Dryer Solenoid Valve Compressor Condenser Water Out Faucet WL200 TOWER WATER FLOW DIAGRAM...

Страница 11: ...erature and the range is approximately 20 F thru the full range of adjustment 7 00 to the 5 00 positions You should be able to turn the screw from the factory set point of 41 F 12 00 position about 45...

Страница 12: ...nd check exterior for damage Sanitizing Sanitize using a Household Bleach 5 25 Sodium Hypochlorite solution or other approved cleaner throughout the cold and sparkling water circuits Follow all instru...

Страница 13: ...nd specified to do the job given the local water conditions usage maintenance schedule and placement restrictions In order for the filters to perform as represented and to provide the best quality wat...

Страница 14: ...faucet of the WL200 11 Flush the Cold Tank Run several gallons of water through the faucet by dispensing cold water to dilute and remove the sanitizer from the cold circuit You can use chlorine test s...

Страница 15: ...Red Power Switch to disable compressor O OFF Turn off Water Supply and Bleed Water Pressure 2 Isolate the unit from feed water by turning off the supply 3 Dispense cold still water to relieve any pre...

Страница 16: ...Installation and Service Manual Page 16 Revision 4 13 2016 8 Disconnect tubing from inlet elbow from solenoid and allow water to drain 9 Reconnect tubing into inlet elbow 10 Dry inside of unit 11 Repl...

Страница 17: ...ater Supply and Bleed Water Pressure 2 Isolate the unit from feed water by turning off the supply 3 Dispense cold still water to relieve any pressure built up in the system 4 Remove the water supply l...

Страница 18: ...w 35 F 2 C Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser t...

Страница 19: ...of water is obtained Once a continuous flow is obtained release the dispensing button Cold tank is now full 5 Move the Waterlogic WL200 into its final operating position Be sure that a minimum of 2 cl...

Страница 20: ...or damage DANGER HIGH VOLTAGE ELECTRICAL HAZARD Unplug before inspection and service 2 Ensure there is adequate minimum of 2 clearance around the unit and clean the condenser grill and compressor fan...

Страница 21: ...WL200 Operating Installation and Service Manual Page 21 Revision 4 13 2016 WL200 COUNTER TOP DRAWINGS with PART NUMBERS Wetted Parts...

Страница 22: ...CT 2016 Cold Tank Thermostat included with Cold Tank 12 1101 Yes 4 ST 8216 Silver Back Panel Counter Top Only 12 8061 Yes 5 EL 5016 Power Line Noise Filter ElectroMagnetic Interference filter EMI 10...

Страница 23: ...Feet Counter Top Only 12 3150 Yes 13 PU 4008 A 1 4 Union Elbow John Guest P N P10308S Purchase from John Guest No 14 PU 4016 Solenoid Valve 1000 mm 12 1500 Yes 14 1 CU 0001 Solenoid Cushion CU 0001 Ye...

Страница 24: ...8605 Yes 21 PL 1100 Silicon Button Key Mat Cold only 12 8600 Yes 22 PL 0084 L00 CL Front Upper Insert Panel Charcoal NA No 23 LP 7085 Button Label Cold only 12 8610 Yes 24 PL 1152 Drip Tray Grill Char...

Страница 25: ...Counter Top Only 12 3165 Yes 32 CT 2060 2L UV Cold Tank Assembly Counter Top Only 12 3110 Yes 33 EN 6111 A Leak Detection PCB NA No 33 1 EN 6059 PCB Stand off Pin 10 3017 Yes 34 PU 4007 A 5 16 x Reduc...

Страница 26: ...WL200 Operating Installation and Service Manual Page 26 Revision 4 13 2016 WL200 TOWER DRAWINGS with PART NUMBERS Wetted Parts...

Страница 27: ...15A with One Wire EL 5053 Yes 3 1 EL 5010 Fuse 120V 15A 10 3013 Yes 4 EL 5019 A Red Power and Compressor Switch 12 5600 Yes 5 CT 2016 Cold Tank Thermostat included with Cold Tank 12 1101 Yes 6 ST 813...

Страница 28: ...12 1500 Yes 13 1 CU 0001 Solenoid Cushion CU 0001 Yes 14 PU 4008 A 1 4 Union Elbow John Guest P N P10308S Purchase from John Guest No 15 PU 4007 A 5 16 x Reducing Elbow John Guest P N PI211008S Purcha...

Страница 29: ...146 Front Upper Drip Tray Insert Panel 12 8050 Yes 21 EN 6086 PCB for Cold Water 12 8615 Yes 22 PL 1180 CN PCB Cover 12 8605 Yes 23 PL 1100 Silicon Button Key Mat Cold only 12 8600 Yes 24 PL 0084 L00...

Страница 30: ...2017 4L Single Cold Tank Assembly Tower Only 12 1100 Yes 30 EL 5003 A Power Transformer 120V 12 3117 Yes 31 ST 8136 R2 Upper Shelf Tower Only 12 8003 Yes 32 CO 9027 Wire Condenser Tower Only 12 8102 S...

Страница 31: ...Service Manual Page 31 Revision 4 13 2016 WL200 COUNTER TOP ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technic...

Страница 32: ...and Service Manual Page 32 Revision 4 13 2016 WL200 TOWER ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technician...

Страница 33: ...run out of cold water Cold tank capacity is 4 liters for Tower and 2 liters for Counter Top Wait for cold tank to chill water to temperature prior to dispensing more cold water A greater capacity of W...

Страница 34: ...mer Black Power Connector to the PCB is not properly connected Properly connect Bad Front PCB Replace Front PCB Part Number EN 6086 Waterlogic P N 12 8615 Defective Red Power Compressor Switch Replace...

Страница 35: ...ition Turn Red Power and Compressor Switch on I ON Compressor Starting Circuit Turn Red Power and Compressor Switch off O OFF Remove the compressor cap on side of the compressor Disconnect the black a...

Страница 36: ...ng won t stop when not holding the Dispensing Button 3 Steady Drip out of Faucet 4 Water does not dispense from unit 5 Cold Water dispenses from Faucet and Vent Outlet Simultaneously 6 Small amount of...

Страница 37: ...PCGB or Solenoid Connector Check that they are connected properly and tightened Solenoid If both the Water Pressure and PCB have been ruled out then it is the Solenoid Replace Solenoid Dispensing butt...

Страница 38: ...ch on unit is in the off position Turn Red Power and Compressor switch on I ON 15 Amp Fuse Blown Replace the 15 Amp Fuse as needed Water is present in the bottom tray causing the leak detection to tri...

Страница 39: ...enses from Faucet Automatically Possible Reason Solution Cold or Hot Water solenoid valve malfunction Inspect valve components for proper function Replace as necessary Obstruction in solenoid housing...

Страница 40: ...leased to the faucet The inlet solenoid controls flow into the tanks The tanks will depressurize once the dispense button is released the inlet solenoid closes A small amount of water will Run On thro...

Страница 41: ...tion to Waterlogic for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporting...

Отзывы: