WL200
Operating,
Installation,
and
Service
Manual
Page
33
‐
Revision:
4
‐
13
‐
2016
COLD
WATER
TROUBLESHOOT
INDEX
1.
Cold
Water
is
not
Cold
(41
°
+/
‐
5
°
F)
Cold
Water
is
not
Cold
(41
°
+/
‐
5
°
F)
Possible
Reason
Solution
No
power
or
refrigeration
elements
Check
that
the
Red
Power
and
Compressor
switch
is
on.
Turn
Red
Power
and
Compressor
Switch
on.
I
=
ON
Tank
has
run
out
of
cold
water.
Cold
tank
capacity
is
4
liters
for
Tower
and
2
liters
for
Counter
Top.
Wait
for
cold
tank
to
chill
water
to
temperature
prior
to
dispensing
more
cold
water.
A
greater
capacity
of
Waterlogic
Water
Systems
is
available.
Cold
Water
Thermostat
Check
continuity
of
thermostat
with
multimeter.
Replace
thermostat
as
required.
Refrigerant
has
run
out
Run
compressor
for
at
least
ten
minutes.
If
condenser
is
not
warm
then
refill
the
refrigerant.
Compressor
problem
If
compressor
is
not
running,
repair
or
replacement
is
needed.