WL200
Operating,
Installation,
and
Service
Manual
Page
12
‐
Revision:
4
‐
13
‐
2016
PRE
‐
INSTALLATION
PROCEDURES
DANGER!
ELECTRICAL
SHOCK
HAZARD.
Only
qualified
personnel
who
have
read
and
understand
this
entire
manual
should
attempt
to
install,
or
service
this
unit,
failure
to
do
so
could
result
in
death
or
serious
injury.
DO
NOT
plug
into
an
electrical
supply
until
specifically
instructed.
WARNING!
ALWAYS
SANITIZE
BEFORE
USE.
Sanitize
before
use
to
eliminate
any
potential
microbiological
contaminates.
Materials
Needed:
Personal
Protective
Equipment.
Rubber
or
Nitrile
Safety
Gloves
and
Protective
Eyewear
Phillips
Screwdriver
Temperature
Gage
Water
Pitcher
or
Container
to
collect
water
from
the
faucet
5
gallon
container
or
drain
basin
Sanitizer
‐
Household
Bleach
(5.25%
Sodium
Hypochlorite)
or
Citric
Acid
Based
Cleaner
¼”
Plastic
Tubing,
at
least
4
feet
in
length,
and
assorted
¼”
quick
connect
fittings
TDS
Meter
and
Test
Strips
for
measuring
chlorine
‐
Optional
1.
Unpack
the
Waterlogic
WL200
and
check
exterior
for
damage.
Sanitizing
Sanitize
using
a
Household
Bleach
(5.25%
Sodium
Hypochlorite
solution)
or
other
approved
cleaner
throughout
the
cold
and
sparkling
water
circuits.
Follow
all
instructions
on
the
sanitizer
and
flush
with
fresh
water
through
the
faucet
until
odor
and
taste
is
acceptable.
WARNING!
USE
PROPER
PERSONAL
PROTECTIVE
EQUIPMENT
Always
ensure
proper
ventilation
and
use
proper
personal
protective
equipment
such
as
gloves
and
eye
protection
when
using
chemicals.
Refer
to
Material
Safety
Data
Sheet
for
specific
requirements
of
each
chemical
product.
Take
all
necessary
precautions
to
prevent
sanitizer
from
contacting
eyes,
clothing,
and
any
other
surfaces
in
could
damage
(carpets).
2.
Put
1
teaspoon
of
sanitizer
per
directions
or
use
Bleach
Solution
(1
teaspoon
=
1/6
oz.
=
5
ml
=
½
cap
full)
of
household
bleach
(Sodium
Hypochlorite
5
‐
10%
Concentration)
in
the
Sanitizing
Cartridge.
Always
ensure
sanitizer
is
compatible
with
stainless
steel
and
acetyl
plastic.
3.
Connect
sanitizing
cartridge
to
inlet
water
supply
and
connect
to
inlet
bulkhead
fitting
on
back
of
unit.
Turn
on
water
supply.
4.
Connect
power
to
WL200
.
DO
NOT
TURN
ON
RED
POWER
SWITCH
AT
THIS
TIME
O
=
OFF
.