RESETTING THE HOT TANK OVERLOAD OR HIGH LIMIT SAFETY
1.
Red Compressor/Heater Switch must be in the
O=OFF
position
2.
Unplug the Power Cord from rear of unit.
3.
Remove the Lower Front Panel of unit by removing the Phillips head screws underneath
the Lower Front Panel.
4.
Locate the Protective Metal Box on the rear of the Hot
Tank. As you look through the Condenser coils on the
rear of the unit, you will see the Hot Tank located on
the right‐hand side.
5.
From the front of the
WL100 Water Treatment System
,
reach up behind the Hot Tank and take hold of the
Protective Metal Box covering the Thermostat and
overload on the Hot Tank.
There are nuts that secure the Protective Metal Box to
the Hot Tank, are loose enough to allow you to remove
the Protective Metal Box.
If the nuts on the metal box are too tight, loosen the
nuts securing the Hot Tank to the Upper Base of the
WL100 Water Treatment System
unit and lower the
Hot Tank so you can remove the Protective Metal Box.