WL100
Manual Page 52 Revision: 1‐14‐2019
2.
Dispensing Won’t Stop When Not Holding the Dispensing Button
Possible Reason
Solution
Too much water pressure.
Recommend 40 to 60 psi for
the
WL100 Water Treatment
System
to operate properly.
Check water pressure at the inlet bulkhead with a water pressure
gauge.
Additional method of verification is to turn off water to unit and
press the dispense button. Does the Solenoid open without water
pressure to the unit? Listen for Solenoid to activate, not to
mistaken for the button “click”.
Adjust water pressure to 40‐60 psi.
The correct input water
pressure is critical to the performance of the unit to allow
Solenoids to open.
Stem of the switch is broken
on the PCB ‐ Printed Circuit
Board.
Remove Display PC and inspect switches.
Replace Display PCB if switches appear broken.
Part Number 20‐0040 (Factory PN EN‐6130)
Debris in the Solenoid
Inspect Solenoid for debris and clean out as needed.
Dispensing Button Stuck
Dirt or Foreign material is filling the gap around the push‐buttons.
Inspect the push buttons and clean surrounding area. Inspect
faucet assembly inside the unit and clean as necessary.
3.
Steady Drip Out of Faucet
Possible Reason
Solution
Debris in Solenoid
Inspect Solenoid for debris and clean out as needed.