INSTALLATION PROCEDURES
Safety and Installation Guidelines
Ensure all Local, State, and Federal Laws and Codes including health and safety guidelines are met
when installing
Waterlogic
Equipment. Only qualified service technicians should attempt
installation and service of
Waterlogic
Equipment.
DANGER!
ELECTRICAL SHOCK HAZARD
.
Always use a dedicated and properly grounded outlet.
Unit should be protected by ground‐fault circuit interrupter (GFCI) or residual current device (RCD)
having a rated residual operating current not exceeding 30mA. Use only Waterlogic supplied
power cord. Never use extension cords or power strips to connect unit. Do not use if the power
supply cord is damaged. Always unplug from power supply prior to servicing.
CAUTION!
INDOOR USE ONLY.
Never expose to direct sunlight, heat sources, or ambient air
temperature above 37°C (100°F) or below 2°C (35°F). Install indoors and keep unit away from
excessive humidity. Never expose to freezing temperatures. Ensure there is adequate clearance
around the unit to allow refrigeration system condenser to dissipate heat. Warmer environments
require more clearance around the unit. Minimum clearance around all surfaces of the machine is
2‐inches. Installs where the ambient temperature exceeds 27°C (80°F), require a minimum of 4‐
inches clearance for proper heat dissipation and efficient operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic
will not be responsible for injury or
damage caused by excessive water pressure. Operating pressure must be 40 psi to 60 psi. Be
aware any of potential pressure surges caused by building/municipal pumping stations.
CAUTION!
USE UV STABILIZED SUPPLY LINES.
Feed the unit with a potable ambient or cold
water supply only.
Feed water over 37°C (100°F) can damage the treatment components. Water
block devices and external leak detectors are strongly recommended. Locate the unit as close to
the water supply and the electrical connections as possible. Locate the unit as close to the water
supply and the electrical connections as possible. Immediately isolate or close water supply valve
and contact service representative if leak is noticed.
WARNING!
STORE AND TRANSPORT UNIT EMPTY.
ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any
potential microbiological contaminates
Pre‐installation and sanitization procedures as prescribed in this manual must be performed before
installing the
WL100 Water Treatment System
.
Always install indoors and place the
Waterlogic WL100 Water Treatment System
on a firm, flat and
stable surface.
1.
Attach the water supply line to the 1/4” feed water Inlet Bulkhead Fitting on the back of the unit.
Waterlogic
requires the use of a water pressure regulator. Water feed pressure must be
between 40‐60 psi. Turn on the water supply and check for leaks.